FEATURES
CABINET
Heavy gauge steel cabinet with five station metal wash
E
process.
Louvered heavy gauge steel panels surround unit on all
four sides to prevent damage to the coil.
Powder paint finish provides superior rust and corrosion
protection.
Control box is conveniently located with all controls
factory wired.
Corner patch plate allows access to compressor
components.
Drainage holes are provided in base section for
moisture removal.
PermaGuard™ Unit Base
Durable zinc-coated base section resists rust and
corrosion.
Refrigerant Line Connections, Electrical Inlets,
F
Service Valves
Sweat connection suction and liquid lines are located on
corner of unit cabinet.
Fully serviceable brass service valves prevent corrosion
and provide access to refrigerant system. Suction valve
can be fully shut off, while liquid valve may be front
seated to manage refrigerant charge while servicing
system.
Refrigerant line connections and field wiring inlets are
located in one central area of cabinet for easy access.
See dimension drawing.
FIELD WIRING
DISCONNECT
SWITCH
(By Others)
B
LENNOX
AIR
CONDITIONER
A - Two Wire Power (not furnished). See Indoor Unit Electrical Data
B - Two Wire Power (not furnished). See Electrical Data
C - Four Wire Low Voltage (not furnished). 18 ga. minimum
D - Five Wire Low Voltage (not furnished). 18 ga. minimum
All wiring must conform to NEC or CEC and local electrical codes.
DISCONNECT
THERMOSTAT
SWITCH
(Optional)
(By Others)
A
D
C
LENNOX
HEATING UNIT
OR
AIR HANDLER
UNIT
Optional Accessories
Unit Stand-Off Kit
Black high density polyethylene feet are available to
raise unit off of mounting surface away from damaging
moisture.
Four feet are furnished per order number.
INSTALLATION CLEARANCES - IN. (MM)
See NOTES
See
NOTES
See NOTES
NOTES:
Service clearance of 30 in. (762 mm) must be maintained on
one of the sides adjacent to the control box.
Clearance to one of the other three sides must be
36 in. (914 mm)
Clearance to one of the remaining two sides may be
12 in. (305 mm) and the final side may be 6 in. (152 mm).
A clearance of 24 in. must be maintained between two units.
48 in. (1219 mm) clearance required on top of unit.
ML14XC1 - 1.5 to 5 Ton Air Conditioner / Page 5