Lennox MERIT ML14XC1 Manual page 3

Advertisement

FEATURES
REFRIGERATION SYSTEM
R-410A Refrigerant
Non-chlorine, ozone friendly, R-410A.
Unit pre-charged with refrigerant.
See Specification table.
B
Outdoor Coil Fan
Direct drive fan moves large air volumes uniformly
through entire condenser coil for high refrigerant cooling
capacity.
Vertical air discharge minimizes operating sounds and
eliminates damage to lawn and shrubs.
Fan motor has sleeve bearings (-018 through -048
and -060 models), ball bearings (-059 model) and is
inherently protected.
Motor totally enclosed for maximum protection from
weather, dust and corrosion.
Rain shield on motor provides additional protection from
moisture.
Louvered steel top fan guard furnished as standard.
Fan service access accomplished by removal of top
panel.
High Pressure Switch
Shuts off unit if abnormal operating conditions cause the
discharge pressure to rise above setting.
Protects compressor from excessive condensing
pressure.
Manual reset.
Lennox Quantum™ Coil
C
Enhanced aluminum alloy tube/enhanced fin coil for
superior corrosion resistance.
Lennox designed and fabricated coil.
Ripple-edged aluminum fins.
Aluminum tube construction.
Lanced fins provide maximum exposure of fin surface to
air stream resulting in excellent heat transfer.
Fin collars grip tubing for maximum contact area.
Flared shoulder tubing connections/silver soldering
construction.
Coil is factory tested under high pressure to ensure
leakproof construction.
Steel louvered panels provide complete coil protection.
Panels can be completely removed for servicing.
High Capacity Liquid Line Drier
Furnished with unit for field installation.
Approved for use with R-410A systems.
Traps any moisture or dirt that could contaminate the
refrigerant system.
Refrigerant Flow Control
Units applicable to
expansion valve
systems or RFC
systems when
matched with
O−RING
specific indoor coils.
RFCIV:
Accurately meters
refrigerant in
system.
Refrigerant control
is accomplished by exact sizing of refrigerant metering
orifice.
The principle involves matching indoor coil with proper
bore size of orifice in metering device.
Equalizes pressure shortly after compressor stops, unit
starts unloaded, eliminating need for additional controls.
Furnished with air conditioner.
Optional Accessories
Expansion Valve Kits
Must be ordered extra and field installed on certain
indoor units. See Refrigerant Metering Devices table.
Chatleff-style fittings.
Freezestat
Installs on or near the vapor line of the indoor coil or on
the suction line.
Senses suction line temperature and cycles the
compressor off when suction line temperature falls
below it's setpoint.
Opens at 29°F and closes at 58°F.
Loss of Charge Switch Kit
Helps protect the compressor from damage due low
refrigerant charge conditions.
SPST, normally-closed switch, automatic reset switch
mounted on suction line.
Refrigerant Line Kits
Refrigerant lines (suction & liquid) are shipped
refrigeration clean. Lines are cleaned, dried,
pressurized and sealed at factory.
Suction line fully insulated.
Lines are stubbed at both ends.
Not available for -059-060 models. Must be field fabricated.
ML14XC1 - 1.5 to 5 Ton Air Conditioner / Page 3
RFCIV METERING SYSTEM
RFCIV
ORIFICE BODY
(On Coil)
ORIFICE
LIQUID
LINE
LIQUID
LINE SCREEN
SEAL
NUT
SWEAT
CONNECTION