(3-6-1 -2) TEMPO CONTROL
I
(3-6-3-1 -2) XG PARMETER CHANGE
binary
11110000
hexadecimal
FO
Exclusive status
binary
11110000
hexadecimal
FO
Exclusive status
01000011
43
YAMAHA ID
01000011
43
YAMAHA ID
01111110
7E '
Style
OOOlnnnn
IN
Device Number
00000000
01
01001100
4C
Model ID
Ottttttt
TT
Tempo4
Oaaaaaaa
AA
Address High
Otutttt
TT
Tempo3
Oaaaaaaa
AA
Address Mid
Ottttttt
TT
Tempo2
Oaaaaaaa
AA
Address Low
Ottttttt
TT
Tempo 1
Oddddddd
DD
Data
11110111
F7
End of Exclusive
1
1
The internal clock will be set to the received Tempo value.
Tempo Meta Event is a large data block (24-bit), it is divided into 4 groups with 7-biis
going into each of the Tempos 1-4 (4 receives the remaining 3 bits).
(3-6-2) UNIVERSAL SYSTEM EXCLUSIVE
(3-6-2-1) UNIVERSAL REALTIME MESSAGE
{3-6-2-1-1) MIDI MASTER VOLUME (Recive only)
binary
hexadecimal
11110000
FO
Exclusive status
01111110
7F
Universal Realtime
01111111
7F
ID of target Device
00001001
04
Sub-ID #l=Device Control Message
00000001
01
Sub-ID #2=Master Volume
Osssssss
SS
Volume LSB
Ottttttt
TT
Volume MSB
11110111
F7
End of Exclusive
11110000
FO
Exclusive status
OllUUO
7F
Universal Realtime
Oxxxnnnn
XN
When N is received N=0-F, whichever is received.
When N is transmitted N always=0.
X = don't care
00001001
04
Sub-ID # 1 =Device Control Message
00000001
01
Sub-ID #2aMaster Volume
Osssssss
SS
Volume LSB
Ottttttt
TT
Volume MSB
11110111
F7
End of Exclusive
The volume for all channels will be changed simultaneously.
The TT value is used as the MIDI Master Volume value, (the ss value is ignored.)
(3-6-2-2) UNIVERSAL NON REALTIME MESSAGE
(3-6-2-2-1) GENERAL MIDI SYSTEM ON
binary
hexadecimal
11110000
FO
Exclusive status
01111110
7E
Universal Non-Realtime
01111111
7F
ID of target Device
00001001
09
Sub-ID #l=General MIDI Message
00000001
01
Sub-ID #2=General MIDI On
11110111
F7
End of Exclusive
11110000
FO
Exclusive status
01111110
7E
Universal Non-Realtime
Oxxxnnnn
XN
When N is received N=0-F, whichever is received.
When N is transmitted N always=0.
X = don't care
0000I001
09
Sub-ID #l=General MIDI Message
00000001
01
Sub-ID #2=General MIDI On
11110111
F7
End of Exclusive
Depending upon the received ON message, the System Mode will be changed to XG.
Except MIDI Master Tuning, all control data be reset to default values.
This message requires approximately 50ms to execute, so sufficient time should be
allowed before the next message is sent.
The bank select message for the channel 10 and the NRPN messages are not received
in the GM mode.
(3-6-3) XG STANDARD
{3-6-3-1) XG PARAMETER CHANGE
(3-6-3-1-1)XG SYSTEM ON
binary
hexadecimal
11110000
FO
Exclusive status
01000011
43
YAMAHA ID
OOOlnnnn
IN
Device Number
01001100
4C
Model ID
00000000
00
Address High
00000000
00
Address Mid
OllllllO
7E
Address Low
00000000
00
Data
llllOlll
F7
End of Exclusive
Depending upon the received ON message, the SYSTEM MODE will be changed to
XG.ControlIers will be reset, all values of Multi Part and Effect, and All System values
denoted by "XG" data within All System will be reset to default values in the table.
This message requires approximately 50ms to execute, so sufficient time should be
allowed before the next message is sent.
11110111
F7
End of Exclusive
For parameters with data size of 2 or 4. transmit the appropriate number of data bytes.
For more information on Address and Parameters, refer to < Table 1 -2 > ~ < Table I -6 >
(pages 42-45).
The 4 data types listed below are transmitted and received.
(These are transmitted only after a Parameter change request is received.)
XG System Data
Multi Effect Data
Multi Part Data
Drums Setup Data
(3-6-3-2) XG BULK DUMP
binary
hexadecimal
IIMOOOO
FO
Exclusive status
01000011
43
YAMAHA ID
OOOOnnnn
ON
Device Number
OIOOUOO
4C
Model ID
Obbbbbbb
BB
ByieCount
Obbbbbbb
BB
ByteCount
Oaaaaaaa
AA
Address High
Oaaaaaaa
AA
Address Mid
Oaaaaaaa
AA
Address Low
Oddddddd
1
DD
1
Data
1
Occccccc
1
CC
Check sum
IIIIOII!
F7
End of Exclusive
For more information on Address and Byte Count, refer to < Table 1-2 > - < Table 1-6 >
(pages 42-45).
The Check Sum value is set such that the sum of Byte Count, Address, Data, and
Check Sum has value zero in its seven least significant bits.
If the top of the block is appointed to the Address the XG Bulk Dump, Bulk Request
will be received.
The Block is a unit that consists of the data, arranged In the list, as the Total Size.
'TTie 5 data types listed below are transmitted and received.
(These are transmitted only after a Bulk Dump request is received.)
System Data
Multi Effect Data (Individual effect unit)
Multi Part Data (Individual part unit)
Drums Setup Data (Individual note unit)
System Information (Individual only)
{3-6-3-3) XG PARAMETER REQUEST (Recive only)
binary
hexadecimal
IlilOOOO
FO
Exclusive status
01000011
43
YAMAHA ID
001Innnn
3n
Device Number
01001100
4C
Model ID
Oaaaaaaa
AA
Address High
Oaaaaaaa
AA
Address Mid
Oaaaaaaa
AA
Address Low
llllOlll
F7
End of Exclusive
For more information on Address and Byte Count refer to < Table 1 -2 > ~ < Table I -6 >
(pages 42-45).
The 4 data types listed below are received.
System Data
Multi Effect Data
Multi Part Data
Drums Setup Data
(3-6-3-4) XG DUMP REQUEST (Recive only)
binary
hexadecimal
11110000
FO
Exclusive status
01000011
43
YAMAHA ID
OOlOnnnn
2n
Device Number
OIOOUOO
4C
Model ID
Oaaaaaaa
AA
Address High
Oaaaaaaa
AA
Address Mid
Oaaaaaaa
AA
Addre.ss Low
1.1110111
F7
End of Exclusive
For more information on Address and Byte Count refer to < Table I -2 > ~ < Table 1 -6 >