Sinclair SDV 6 User & Installation Manual

Commercial air conditioners
Hide thumbs Also See for SDV 6:

Advertisement

Quick Links

USER & INSTALLATION MANUAL
SWC-63
C O M M E R C I A L A I R C O N D I T I O N E R S S D V 6

Advertisement

Table of Contents
loading

Summary of Contents for Sinclair SDV 6

  • Page 1 USER & INSTALLATION MANUAL SWC-63 C O M M E R C I A L A I R C O N D I T I O N E R S S D V 6...
  • Page 2: Table Of Contents

    This manual gives detailed description of the precautions that should be brought to your attention during operation. In order to ensure correct service of the wired controller please read this manual carefully before using the unit. For convenience of future reference, keep this manual after reading it. CONTENTS GENERAL SAFETY PRECAUTIONS About the documentation...
  • Page 3 5 OTHER FUNCTIONS AND SETTINGS 6 FAQ 7 INSTALLATION Installation Precautions Installation Method 8 ENGINEERING SETTINGS Parameter settings of the wired controller Engineering Menu Wired controller Configuration IDU settings ODU settings...
  • Page 4: General Safety Precautions

    1 GENERAL SAFETY PRECAUTIONS 1.1 About the documentation The original documentation is written in English. All other languages are translations. The precautions described in this document cover very important topics, follow them carefully. All activities described in the installation manual must be performed by an authorized installer.
  • Page 5: For The User

    CAUTION Indicates a situation that could result in minor or moderate injury. NOTE Indicates a situation that could result in equipment or property damage. INFORMATION Indicates useful tips or additional information. 1.2 For the user If you are not sure how to operate the unit, contact your installer. The appliance is not intended for use by persons, including children, with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction...
  • Page 6 NOTE Do NOT place any objects or equipment on top of the unit. Do NOT sit, climb or stand on the unit. Units are marked with the following symbol: This means that electrical and electronic products may not be mixed with unsorted household waste.
  • Page 7: Basic Parameters

    2 BASIC PARAMETERS Items Description Rated voltage DC18V Wiring size RVVP-0.5mm ×2 Operating environment -5°C ~ 43°C Humidity ≤ RH90% 3 ACCESSORIES LIST Name Quantity Wired controller Philips head screw, M4×25 Installation and Operation Manual Plastic support bar Bottom cap of the wired controller Round head screw ST4X20 Plastic expansion pipe...
  • Page 8: Operation Instructions

    4 OPERATION INSTRUCTIONS 4.1 Control Panel Explanation On/off Menu Display Information Left Back Down Right Enter...
  • Page 9: Basic Operation

    Basic Operation Press " On/Off ". The interface/operation button will light up 1. On/Off and the device will start. Under one-to-many individual control, the screen will not die when the power-off button is pressed. Press " On/Off " again. The screen/operation button will be off, and the device will shut down.
  • Page 10 Sleep Sterilization Aux heater Comfort 3D circulating air Avoid people Blow on people Silent IDU Backup running Fault prompt Key lock Lock mode Schedule Rapid cooling Rapid heating Air quality monitoring:good,middle,poor...
  • Page 11: Mode

    Mode Cold Mode Select the mode on the menu and press " " for confirmation. After entering the mode, press " " or " " to select the operating mode, and press " " for confirmation. Or press " Back " to exit. Mode conflict: 1.
  • Page 12: Fan Speed

    4.4 Fan speed speed speed Auto Select the fan speed on the menu, and press " " for confirmation. After entering the fan speed interface, press " " or " " to select the operating speed, or press " Back " to return to the menu. CAUTION Depending on IDU models, 3 speeds or 7 speeds are supported.
  • Page 13: Swing

    4.5 Swing Vertical swing Vertical swing Auto Auto Select the swing (up/down) left/right function on the menu, and press " " for confirmation. After entering the swing interface, press " " , " ", " " or " " to adjust the swing angle, or press " Back " to return to the menu.
  • Page 14 Independent swing Vertical Individual swing Louver 1 Louver 2 Louver 3 Louver 4 Select the swing up/down function on the menu, and press " " for confirmation. After entering the swing interface, press " " or " " to select the air outlet to be controlled, or press " "...
  • Page 15: Timer

    4.6 Timer Horizontal Timer Timer OFF 2.5h Timer ON Menu-schedule Delayed OFF 30min Select the timer function on the menu, and press " " for confirmation. After entering the timer interface, press " " or " " to select the corresponding timer, and press "...
  • Page 16 Menu-schedule Menu-schedule Schedule 1 Schedule state schedule1 Cycle Work day schedule2 Set cmds schedule3 Simple Schedule Menu-schedule include three regular schedules(the first,second and third) and simple schedule, you can set the schedule on/off to enable or not, the Repeating date, and the schedule act. Press " "...
  • Page 17 Set act Set cmds Set cmds 00:00 26.0Ⅸ 05 00 ON 00:00 26.0Ⅸ 26.0Ⅸ 28.0Ⅸ 05:00 26.0Ⅸ 28.0Ⅸ (1) Simple Schedule You can set up to five acts, each of which contains the time and power-on/off information. Press " " or " "...
  • Page 18 CAUTION There should not be more than one schedule act at the same time. Otherwise, a conflict may occur. Complete the date setting before the first schedule setting. Delayed off This function is only effective after the schedule is enabled. After delayed off is set, the air conditioner will delay its shutdown in accordance with the set delay based on the original schedule power-off time.
  • Page 19: Self-Cleaning

    4.7 Self-cleaning Self-cleaning Self-cleaning for 25 minutes Long press cancel Select the self-cleaning function on the menu. The self-cleaning process takes approximately 50 minutes and falls into four steps: Pretreatment Icing De-icing and Rinsing Drying CAUTION You can quit the timer by long pressing " "...
  • Page 20: Eta Function

    4.8 ETA function Select the ETA function on the menu, and press " " to enable or disable the ETA function. The ETA function is real-time energy saving.
  • Page 21: Air Quality Monitoring

    4.9 Air quality monitoring Air quality monitoring Air quality monitoring 1000ppm 75¤g/m ³ PM2.5 00001mg/m ³ HCHO Select the air quality function on the menu, and check the air quality indicators such as AQI, PM2.5 and CO in real time. Indoor air quality monitoring requires adequate configuration of the IDU.
  • Page 22: Function Settings

    4.10 Function settings Setting Setting Sterilization Wind sensing... Sleep Select the function setting on the menu, and press " " for confirmation. After entering the function setting interface, press " " or " " to switch the function, and press " "...
  • Page 23 Sleep: After sleep is enabled, the home page will show a sleep icon. The sleep function is only applicable to cooling and heating modes and unavailable for auto, dry and fan modes. With sleep enabled, it will be cancelled after manual power-off or mode switching.
  • Page 24 CAUTION Auto Operation of Auxiliary heat source: Upon power on, the air conditioner will determine whether to start the auxiliary heat source automatically based on the ambient temperature in heating mode. At this moment, the air conditioner operates in "Auto Operation of Auxiliary heat source" mode. Auxiliary heat source Used Independently: The auxiliary heat sourcecan be used independently without starting the compressor.
  • Page 25 Wind sensing of smart panel : The wired controller can set the IDU air flow to "Comfortable" or "Off". If the air flow is set to "Comfortable", the fan speed and swing angle of the IDU will automatically adjust to a relatively comfortable level. This function only applies to IDUs with air flow setting feature.
  • Page 26 5 OTHER FUNCTIONS AND SETTINGS APP control Home leaving mode ECO setting by human sensor Silent IDU Temperature unit setting Room temp.display IDU lighting Backlight time Backlight brt 5.10 The temperature setting in auto mode Key lock 5.11 Daylight saving time 5.12 5.13 Date and time setting...
  • Page 27: App Control

    5.1 APP control Setting Tempe in auto mode Lock APP control Intelligent network Key tone prompt When smart networking is enabled, you can control your smart devices with APP. iLetComfort appliances networking guidelines Download iLetComfort App Scan the QR code below, or search for "iLetComfort" in Google play(Android devices) or App Store (ios devices) to download the app;...
  • Page 28 Register or Login account Open the app and create a user account, if you already have one, just log in. Login Enter email Login Enter password Login Add your appliance Tap the "+"icon to add home appliance to your iLetComfort account.
  • Page 29 Connected to the network Follow the instructions in the app to set up the WiFi connection.If the network connection fails, please refer to the App tips for operation. Connection complete Sure Sure...
  • Page 30 SSID name. A large number of devices on the WiFi router can affect network stability, there is no way that Sinclair can advise a specific number limitation as this depends on router quality and many other factors.
  • Page 31 WARNING Warning and troubleshooting for networking failures: When the product is connected to the network, please make sure that the phone is as close as possible to the product. We only support 2.4GHz band routers at present. Special characters (punctuation, spaces, etc.) are not recommended as part of the WLAN name.
  • Page 32: Home Leaving Mode

    5.2 Home leaving mode Setting Home leaving mode Sterilization G28Ⅸ F5Ⅸ Home leaving mode META setting by human sensor When the Home leaving mode is enabled and Indoor temperature reaches the set value,the air conditioner will activate cooling or heating mode. You can press "...
  • Page 33: Eco Setting By Human Sensor

    5.3 ECO setting by human sensor Setting ECO setting by human sensor Sterilization Stastus Adjust set temp. 45min Temp.change interval Wind sensing... 4Ⅸ Max temp.adjust variance ECO setting by human sensor The ECO setting by human sensor is enabled when no one is detected, You can select the "Staus"...
  • Page 34: Silent Idu

    5.4 Silent IDU Setting Setting Strong mode Strong mode Wind sensing of Wind sensing of smart panel smart panel Silent IDU Silent IDU ・C ・C Temp unit setting Temp unit setting After "Quiet IDU" is enabled, the IDU will operate in silence. You can press "...
  • Page 35: Temperature Unit Setting

    5.5 Temperature unit setting Setting Setting Strong mode Strong mode Wind sensing of Wind sensing of smart panel smart panel Odu silence Odu silence Temp unit setting Temp unit setting ・C ・F The temperature unit is Celsius by default. You can manually switch the unit between Celsius and Fahrenheit.
  • Page 36: Room Temp.display

    5.6 Room temp.display Setting Setting Tempe in auto Tempe in auto mode mode Lock Lock Intelligent network Intelligent network Room temp. Room temp. hide show display display After the Room temp.display is enabled, if you return to the home page and does not operate the device, the device will automatically display the room temperature and presents a room temperature icon.
  • Page 37: Idu Lighting

    5.7 IDU lighting Setting Setting Tempe in auto Tempe in auto mode mode Lock Lock Intelligent network Intelligent network IDU light IDU light After the IDU lighting is enabled, the IDU display LED will light up. After the IDU lighting is disabled, the IDU display LED will turn off. You can press "...
  • Page 38: Backlight Time

    5.8 Backlight time Setting Setting Tempe in auto Tempe in auto mode mode Backlight Backlight 15second 30second time time Intelligent network Intelligent network Key tone prompt Key tone prompt The backlight time can be set to 15s, 30s,or 60s. After the setting, if the device fails to receive any command within the set backlight time, it will enter the standby interface.
  • Page 39: The Temperature Setting In Auto Mode

    5.10 The temperature setting in auto mode Auto mode temp. setting Setting Tempe in auto mode ・C F F ・C Lock Set temp.limits for Intelligent network auto mode Key tone prompt The temperature setting in auto mode enables you to set the temperature in auto cooling/heating mode, and maintain the indoor temperature within the set range.
  • Page 40: Key Lock

    5.11 Key lock Setting Key Lock Tempe in auto mode Key Lock Press[ ]and[ ]at the sametime for Intelligent network 3seconds to on or off the key lock function Key tone prompt The key lock serves to prevent mis-operation of the children. After it is enabled, the buttons of the device will be locked and cannot be operated until the key lock is unlocked.
  • Page 41: Daylight Saving Time

    5.12 Daylight saving time Daylight Daylight saving time saving time Start time Start time 5/23 5/23 End time End time 9/23 9/23 Daylight saving time You can enable or disable daylight saving time, and set the start time and end time. Find daylight saving time in the function setting interface, and press "...
  • Page 42: Date And Time Setting

    5.13 Date and time setting set date Time format 2021 year Use network date Date 2021/5/23 Time 09:00AM Date and time You can select the network time (Internet connection required) or manually set the time. Find the date and time in the function setting interface, find the time display mode, and press "...
  • Page 43 Time setting Time setting Time format o㈩clock Minute o㈩clock Minute Time display Time can be displayed in 12-hour or 24-hour format. Find the date and time in the function setting interface, find the time display mode, and press " " to enter the setting interface.
  • Page 44: One-To-More

    5.14 One-to-more One wired controller can control more than one IDU (up to 16 IDUs). One to more control includes group control and individual control. Under group control, the device sends commands to all IDUs in a unified manner. Under individual control, the device sends commands to any IDU in the system.
  • Page 45 On the main interface of one-to-many individual control, press " back " to quit from such control. Press " " or " " to switch the control object. The control object can be all IDUs or any IDU. Upon selection of the control object, press "...
  • Page 46: Fault Prompt

    5.15 Fault Prompt Fault List C51/E9 communication fault between wired controller and IDU Press "Information" to view error codes on the homepage when fault occurs. Error display Error code:C51 1. In case any IDU or ODU fails, the wired controller displays the fault code.
  • Page 47 6 FAQ The air conditioner is not working, but prompts that neither cooling nor heating option can be set. What should I do? The set mode is inconsistent with the operating mode of ODU. Please change the set mode to cooling/heating. The word "Filter"...
  • Page 48 Why does the air outlet of my air conditioner drip? The room is filled with a great amount of moisture. Please close the doors and windows. Why does the ODU of my air conditioner drip? 1. During cooling in summer, condensation water generated by the unit is discharged to the outside through the IDU drainage pipe.
  • Page 49 Why does air conditioner keep operating after it is powered off? After your air conditioner is powered off, there is some residual moisture inside the conditioner. It operates for a while to eliminate the moisture, so as to reduce the possibility of mould growth. Why are the air conditioner functions non-adjustable? If the display panel presents a centralized controller icon, the air conditioner is locked.
  • Page 50 7 INSTALLATION 7.1 Installation Precautions ● To ensure correct installation, read the "Installation" section of this manual. ● The content provided here covers warnings, which contain important information about safety that must be followed. CAUTION Entrust a local distributor or local service agent to appoint a qualified technician to perform the installation.
  • Page 51 Do not install the wired controller in a wet place and avoid direct sunlight. Do not install the wired controller when it is powered on. Please install the wired controller after painting the wall; otherwise, water, lime and sand may enter the wired controller. 7.2 Installation Method 7.2.1 Wiring requirements One-to-more and two-to-more...
  • Page 52 The one-to-more function must be set for the wired controller. After the communication between the wired controller and IDU lasts 3 minutes and 30 seconds, the control can be implemented. One-to-one ● Applicable to bi-directional communication between wired controller and IDU.
  • Page 53 Two-to-one Applicable to bi-directional communication between wired controller and IDU. Two-to-one: Two wired controller controls one IDU. The parameters displayed on the wired controller are updated in real time according to changes in the parameters of the IDU. Two-to-one: wired controller must be set as main or secondary.
  • Page 54 Installation Dimensions 7.2.2 46mm 120mm 18mm 60mm Installlation of bottom cap of the wired controller. Screw hole installed on the wall,use four φ4X20mm(Fig.4) Or use two M4X25 screws to install the back cover on the 86 electrical box, and use two M4X20 screw to fix to the wall. (Fig.5) Screw hole fixed on the wall, use two φ4X20mm Screw hole installed on 86...
  • Page 55 Adjust the length of the two plastic screw bars in the accessories so there is a uniform distance between the electrical box screw bar and the wall. Make sure that it is as flat as the wall when installing the screw bar to the electrical box screw bar.
  • Page 56 7.2.3 Wire outlet Cutting place of upper side wire outlet DETAIL A SCALE 2:1 Cutting place of lower side wire outlet DETAIL C DETAIL B SCALE 2:1 SCALE 2:1 Wire clamp : For fixing wire trend upper side wire outlet lower side Fig.7 wire outlet...
  • Page 57 46mm Wall hole and wiring hole Wiring hole 60mm Diameter :Φ8--Φ10 Avoid the water enter into the Putty wired remote controller, use Trap Putty Putty trap and putty to seal the connectors of wires during Trap wiring installation. Trap Fig.8 7.2.4 Wiring Installation NOTE The switch box and control wire for 2nd generation IDUs are...
  • Page 58 7.2.5 Front cover installation After adjusting the front cover, buckle the front cover; avoid clamping the communication switching wire during installation. (Fig. 9) Sensor can not be affected with damp Fig.9 Correctly install the back cover and firmly buckle the front and back covers; otherwise, the front cover will fall off.
  • Page 59 8 ENGINEERING SETTINGS 8.1 Parameter settings of the wired controller ● Parameters can be set in the power-on or power-off state. ● Hold " " and " " for 3 seconds to enter the parameter setting interface. ● After entering the parameter setting interface, Press " "...
  • Page 60 8.2 Engineering Menu Menu Submenu Setting Mode disable Auto, Cool, Heat, Fan, Dry Set temp. Lock Speed Room temp. sensor position Room temp. sensor set Room temp. sensor For details, see the "Wired controller Configuration" WDC config For details, see the "IDU settings" IDU set item Set IDU address Set IDU address...
  • Page 61 8.3 Wired controller Configuration Menu Submenu Third-level menu Default Remarks Set main and sec. wired controller main/second Master WDC Set temp. format: 0.5/1 0.5 degree Temp. Adjustment or not Set temp. range/cool and Set upper and lower Common The room heat temp.
  • Page 62 8.4 IDU settings SDV5 protocol IDU set Parameter name Parameter range Remarks item Static pressure setting 00/01~19/FF The IDU sets the static of IDU pressure based on the set gear, FF (VRF unit: main board DIP of IDU; other On-site models: reserved) settings On-site air flow adjustment factor...
  • Page 63 IDU set Parameter name Parameter range Remarks item Set outdoor temperature Celsius: -5 to 20 1°C or 1°C accuracy for auxiliary heat source / Fahrenheit: 23 to 68 Note: Not supported on FAPUs. alternative heat source to turn on 00: No limit; 01: -16°C/4°F; Set outdoor temp.
  • Page 64 IDU set Parameter name Parameter range Remarks item 00/01/02/03/FF Common IDUs (models 1, 3, IDU's anti-cold wind 4, 6, and 8): temperature setting in heating mode 00: 15; 01: 20; 02: 24; 03: 26; FF: Invalid FAPU (models 2 and 7): 00: 14;...
  • Page 65 IDU set Parameter name Parameter range Remarks item IDU cooling temp. VRF unit: VRF unit: 00: 0°C; 01: 2°C; compensation 00/01/FF FF: main board DIP of IDU Split unit: Split uni: 00: 0°C; 01: 1°C; Temp. 00/01/02/03/FF 02: 2°C; 03: 3°C; FF: Reserved setting Mini VRF unit: Mini VRF unit: 00: 0°C;...
  • Page 66 SDV6 protocol IDU set Parameter name Parameter range Remarks item The IDU sets the static pressure Static pressure setting 00/01~19/FF based on the set gear, FF (VRF of IDU unit: main board DIP of IDU; other models: reserved) High ceiling setting 00/01/02 00: 3 m;...
  • Page 67 IDU set Parameter name Parameter range Remarks item Mode changeover interval 00/01/02/03 00: 15min; 01: 30min; in Auto mode (min) 02: 60min; 03: 90min Power failure memory 00/01 00: Not available; for IDU 01: Available Remote control 00/01 00: Receive; 01: Not receive setting instruction receiving on IDU display panel...
  • Page 68 IDU set Parameter name Parameter range Remarks item 00: No limit; Set outdoor temp. 00/01/02/03/04/ 01: -16°C/4°F; when the third-party 05/06/07/08/09/ heater works 10/11/12/13/14/ 02: -14°C/7°F; separately 15/16/17 03: -12°C/10°F; 04: -9°C/15°F; 05: -7°C/20°F; 06: -4°C/25°F; 07: -1°C/30°F; 08: 2°C/35°F; 09: 4°C/40°F;...
  • Page 69 IDU set Parameter name Parameter range Remarks item Indoor temperature for auxiliary 0 to 7 represent 0 to 7°C/°F heat source/alternative heat source to turn on Indoor temperature for auxiliary 0-10 0 to 10 represent -4 to 6°C/°F setting heat source/alternative heat source to turn off IDU control type 00/01/02...
  • Page 70 IDU set Parameter name Parameter range Remarks item IDU's anti-cold wind 00/01/02/03/04 Common IDUs (models 1, 3, temperature setting in 4. 6, and 8): 0: 15; 1: 20; 2: heating mode 24; 3: 26; 04: Invalid Anti-cold wind 00/01/02/03/04 00/01/02/03: corresponds to different temperature setting of values;...
  • Page 71 IDU set Parameter name Parameter range Remarks item 00/01 On/Off port logic via 00: Remote off (closed); remote control 01: Remote off (open) Note: When powered off remotely, the digital display of wired controller of SDV6 displays d6, while that of SDV5 does not display this code Remote ON/OFF control 00/01...
  • Page 72 IDU set Parameter name Parameter range Remarks item Eta level in cooling 00/01/02 00: Level 1; 01: Level 2; mode 02: Level 3 Eta level in heating 00/01/02 00: Level 1; 01: Level 2; Energy mode 02: Level 3 conserva tion Initial static pressure 00/01...
  • Page 73 8.5 ODU settings Parameter name Parameter range Energy rating of ODU 40% to 100%, every 1% VIP IDU address 0-63 Heating and air supply enabled 00: Disable; 01: Enable Silence level of ODU Level 0 to14...
  • Page 76 Kingdom www.sinclair-world.com This product was manufactured in China (Made in China). T E C H N I C A L S U P P O R T SINCLAIR Global Group s.r.o. Purkynova 45 612 00 Brno Czech Republic Tel.: +420 800 100 285 | Fax: +420 541 590 124...

Table of Contents