Configuration Menu
ONLY QUALIFIED PERSONNEL CAN ACCESS THE SERVICE MENU AND MODIFY PARAMETERS.
Access the Main menu [MENU] using the button
Follow the path installer menu [Service] >enter the Password 1234 (see fig. 15). Confirm with the button
Parameter modification menu [TSP]
To scroll the list, press the heating buttons; press the button
ttons, confirm with the button
Table 10- Parameters table
Index
Description
Gas type selection
b01
Boiler type selection
b02
Combustion chamber type selection
b03
Primary Exchanger type selection
b04
Variable output relay operation selection
(b02=1)
b05
No effect on adjustment (b02=2)
No effect on adjustment (b02=3)
No effect on adjustment (b02=4)
Mains Voltage Frequency
b06
Comfort burner on time
(b02=1)
No effect on adjustment (b02=2)
b07
No effect on adjustment (b02=3)
No effect on adjustment (b02=4)
Gas valve driver
b08
DHW demand type selection
b09
70
.
or cancel with the button
Range
0 = Natural gas
1 = LPG
1 = Bithermal instantaneous
2 = Monothermal instantaneous
3 = Heating only (3-way valve)
4 = Heating only (circulating pump)
0 = Sealed Chamber combustion control
(without air Pressure switch)
1 = Open Chamber
(with fume Thermostat)
2 = Sealed Chamber
(with air Pressure switch)
3 = Sealed Chamber combustion control
(with fume Thermostat on recuperator)
4 = LOW NOx Sealed Chamber Combustion control
(without air Pressure switch)
5 = LOW NOx Open Chamber
(with fume Thermostat)
0 - 13
0 = External gas valve
1 = System filling solenoid valve
2 = Solar 3-way valve
3 = Indicator supply with fault present
4 = Indicator supply with no fault
5 = External circulating pump (during demand and
post circulation)
0=50Hz
1=60Hz
0-20 seconds
0 = Standard, 1
0 = Flow switch
1 = Flowmeter (190 imp/l)
2 = Flowmeter (450 imp/l)
3 = Flowmeter (700 imp/l)
cod. 3540000180 - Rev. 00 - 05/2023
DIVATOP D HF
to display the value. To modify, press the DHW bu-
.
Default
0
3
2
4 - DIVATOP D HF24
5 - DIVATOP D HF32
NOT AVAILABLE FOR THIS
MODEL
--
0
--
--
0
--
5
--
--
0
2
.