Ferroli DIVATOP D HF Instructions For Use, Installation & Maintenance page 54

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 44
Display adjustment menu [Display]
Certain display parameters can be set up in this menu.
[Contrast] - Contrast adjustment
[Brightness] - Brightness adjustment
[Backlight time] - Display lighting duration
[Lock time] - Button lock
After keypad inactivity for a time equal to the
set value (minutes), the
and the buttons are inhibited.
To reactivate the keypad, press the
buttons simultaneously until the
symbol disappears (about 2 sec.).
[Reset] - Restore factory values
Sliding Temperature
When the external probe (optional) is installed, the boiler adjustment system works with "Sliding Temperature". In this
mode, the heating system temperature is regulated according to weather conditions, to ensure high comfort and energy
efficiency throughout the year. In particular, as the outside temperature increases the system flow temperature decrea-
ses according to a specific "compensation curve".
With "Sliding Temperature", the temperature set using the heating buttons (details 3 and 4 - fig. 1) becomes the maxi-
mum system flow temperature. It is advisable to set a maximum value to allow system adjustment throughout its useful
operating range.
The boiler must be adjusted at the time of installation by qualified personnel. However, the user can make any further
adjustments necessary to optimize comfort levels.
Compensation curve and curve offset
From the main screen, press the button
heating select the installer menu [SERVICE] and confirm with the button
menu [SERVICE]' on page 52 ***) and press the button
Heating curves setting [OTC] and confirm by pressing the button
Curve: select this item and use the buttons
DHW to set the desired curve from 1 to
10.
By setting the curve to 0, the sliding tempe-
rature adjustment is disabled (see fig. 22).
Offset: Access this sub-menu to access parallel off-
set of the curves using the buttons
DHW. Refer to fig. 23 for the characteris-
tics.
54
symbol appears
and
to access the navigation menu [MENU]. Using the buttons
. Using the buttons
and
and
cod. 3540000180 - Rev. 00 - 05/2023
DIVATOP D HF
DISPLAY
Contrast
5
Brightness
Max
Backlight time
10m
Lock time
OFF
Reset
fig. 20
. Enter the password (see *** 'Installer
and
heating select the menu
.
OTC
Curve
Offset
fig. 21
and
EN