All keypads must be set to a unique address via the
i
node select switch on the keypad and they all must
Note
have a home area programmed to work correctly.
Area 1 is the default Home Area.
Devices > Keypads >
General Options
1
Keypad Extinguish
2
Greetings
3
Enable Egress Input
4
Enable Rear Tamper
5
PIN To Change Area
6
Home Area Only
7
Report/Display Keypad Temperature
8
Display Area ICON Indicators
The above options can be configured independantly for
each keypad fitted to the system.
1) Enter your Installer PIN + [MENU].
2) Enter [6] + [1] + [4] + [OK].
The keypad will display the current options which are
selected or enabled.
2 3
3) Use the numeric keys [1] to [8] to turn on and off
the features as required. When the corresponding
number on the keypad is on then the option is
selected.
4) When all options are programmed, press [OK] to
save and exit, or press [MENU] to exit without
saving.
Keypad Extinguish
Setting this option configures the panel to automatically
turn off the keypad backlighting after an inactivity period
of 60 seconds. As soon as a key is pressed or an alarm
occurs, the keypad backlight will turn on.
Greetings
Setting this option configures the keypad to display
a farewell greeting when the user arms an area or a
welcome greeting when the user disarms an area. The
greeting will include the user name if programmed.
The greeting will reflect the time of day and include the
user name if programmed.
™ Good Morning Greeting = 00:00 to 11:59
™ Good Afternoon Greeting = 12:00 to 17:59
™ Good Evening Greeting = 18:00 to 23:59
Bosch Security Systems 09/11 BLCC500I
L614
MENU 6-1-4
-bit-
7
Solution 16i
Enable Egress Input
This option allows the egress input to operate when
using the CP150B / CP151B external vandal resistant
keypads.
This option is only available with software version
i
2.19 and higher.
Note
N
Y
Enable Rear Tamper
N
Setting this option enables the panel to trigger an
N
alarm when the keypad's inbuilt tamper circuit becomes
N
faulted. A tamper alarm report will be sent to the base
N
station, a tamper alarm restore will be sent when the
Y
tamper has been reset.
N
For this option to work, the keypad model being used
must have the on-board tamper switch fitted.
PIN To Change Area
Setting this option will prevent a user from switching
between different areas on the keypad unless they enter
a valid user PIN.
When this option is not set, users will be able to
change the keypad view to all other areas in the system
regardless of whether or not they have access to those
areas.
Home Area Only
Setting this option will force the keypad to display only
it's assigned home area information. Therefore a user
cannot toggle (or move) the keypad display to show that
of a different area when the system has been partitioned.
Report/Display Keypad Temperature
This option allows the keypad to display and report a
temperature alarm to the base station if the keypads
temperature falls below or rises above the minumum
and maximum temperatures programmed in MENU 7-7-3
— Keypad Hi/Lo Temp.
An output can be programmed to operate when
a keypad hi/low temperature fail condition occurs
irrespective of whether or not this option is set.
See MENU 6-1-5 — Beeper Options to set the keypad to
always show the current temperature in the display.
Display Area ICON Indicators
This option sets the keypad to show the AREA ICON
indicators in the keypad display at all times. The Icons
show the status of all areas on the system without having
to press any keys.
When the Area Icon is ON the corresponding area is
armed and when the Area Icon is OFF or not visible the
corresponding area is disarmed.