(7) Software protect
Set the item "OPERATION"
to "ON" to prevent stored data from being overwritten due to unintended
misoperations, or internal data from being overwritten by received bulk data, parameter changes, etc.
Even if this menu is set to "ON", the memory recall function is enabled.
«DEQS control display example>
SOFTHARE
PROTECT
O GEERATION GFF
(8) RS-485 Program Change table
Create a corresponding table between the Program Change (memory change command) numbers received through
RS-485 circuit and the memory numbers you want to recall by the DEQSE.
Four types (BANK A~D) of tables can be created and the BANK
recalled by this menu is executed.
© BANK coupe
Selects a corresponding table from A to D
e PGM
ini tiit Received Program Change number (1-128)
€ MEM
........................................ Memory number recalled by the DEQSE (1-40)
<DEQS control display example»