Graco 25M480 Instructions Manual page 12

Yuhong electric driver for high pressure airless sprayer
Table of Contents

Advertisement

Troubleshooting
Problem
Driver does not turn
Over voltage (greater than 300 V)
over and LED is off
No power to control board
Driver does not turn
Encoder fault
over and LED is on
Oil is leaking
Oil was over-filled
Drain plug not tightened properly
Seal cartridge o-ring missing or dam-
aged.
12
Cause
Solution
Check power supply
Contact your Graco distributor or Tech Service
for more information.
Cycle power.
Contact your Graco distributor or Tech Service
for more information.
Drain and refill as stated in Check Oil Level,
page 9.
Torque to 18-23 ft-lb (25-30 N•m).
Replace shaft bearing assembly.
3A5173A

Advertisement

Table of Contents
loading

Table of Contents