  • Page 1 PO Box 372 Fax: (973) 786-7586 Andover, NJ 07821 USA sales@kanomax-usa.com Model 6824 ™ THERMO-ANEMOMETER User Manual 6824 ™ User Manual, PN 10283 Kanomax USA, Inc Rev 2.0, 1-Dec-2022 www.kanomax-usa.com Page 1 of 28 Copyright © 2022, Kanomax USA, Inc.
  • Page 2 You now own one of the most accurate, dependable, and highly regarded airflow measurement instruments available today. Kanomax’ s model 6824 digital thermo-anemometer is a versatile instrument for measuring air velocity and temperature in various applications such as HVAC, aerospace development, industrial process airflow, and fluids research.
  • Page 3: Warranty

    Andover, New Jersey 07821 Please include a note with name, address, telephone number and description of the problem. Although we provide assistance on Kanomax products both personally and through our literature, it is still the total responsibility of the customer to determine the suitability of the product for use in their application.
  • Page 4: Important Safety Information

    ESD safe environment may cause damage not covered by the manufacturer’s warranty. Important: Mandatory Action Required The specific action is given near this symbol. 6824 ™ User Manual, PN 10283 Kanomax USA, Inc Rev 2.0, 1-Dec-2022 www.kanomax-usa.com Page 4 of 28 Copyright © 2022, Kanomax USA, Inc.
  • Page 5 We are committed to reduce the negative environmental and human health effects of WEEE. 6824 ™ User Manual, PN 10283 Kanomax USA, Inc Rev 2.0, 1-Dec-2022 www.kanomax-usa.com Page 5 of 28 Copyright © 2022, Kanomax USA, Inc.
  • Page 6 Dropping the instrument or the probe may cause damage or malfunction to the instrument and may change the calibration data. We recommend sending it in immediately to be checked. 6824 ™ User Manual, PN 10283 Kanomax USA, Inc Rev 2.0, 1-Dec-2022 www.kanomax-usa.com Page 6 of 28 Copyright © 2022, Kanomax USA, Inc.
  • Page 7 When storing or shipping the instrument, the manufacturer recommends disconnecting the cable(s) and returning it to the original carrying case. 6824 ™ User Manual, PN 10283 Kanomax USA, Inc Rev 2.0, 1-Dec-2022 www.kanomax-usa.com Page 7 of 28 Copyright © 2022, Kanomax USA, Inc.
  • Page 8: Section 1 - Specifications

    Approx. 150 hours, without backlight Battery check: Automatic low battery display Display: 0.5” LCD, 4 digits, with LED backlight 6824 ™ User Manual, PN 10283 Kanomax USA, Inc Rev 2.0, 1-Dec-2022 www.kanomax-usa.com Page 8 of 28 Copyright © 2022, Kanomax USA, Inc.
  • Page 9: Options Available

    (3) Size AA 1.5V alkaline batteries (installed in instrument) (1) Hard-shell carrying case with foam liner • (1) 6824 operation manuals • 6824 ™ User Manual, PN 10283 Kanomax USA, Inc Rev 2.0, 1-Dec-2022 www.kanomax-usa.com Page 9 of 28 Copyright © 2022, Kanomax USA, Inc.
  • Page 10 219 Route 206 Phone: 1-800-247-8887 PO Box 372 Fax: (973) 786-7586 Andover, NJ 07821 USA sales@kanomax-usa.com Dimensions INSTRUMENT 6824 ™ User Manual, PN 10283 Kanomax USA, Inc Rev 2.0, 1-Dec-2022 www.kanomax-usa.com Page 10 of 28 Copyright © 2022, Kanomax USA, Inc.
  • Page 11 Phone: 1-800-247-8887 PO Box 372 Fax: (973) 786-7586 Andover, NJ 07821 USA sales@kanomax-usa.com APT275 PROBE APT100 PROBE 6824 User Manual, PN 10283 Kanomax USA, Inc ™ Rev 2.0, 1-Dec-2022 www.kanomax-usa.com Page 11 of 28 Copyright © 2022, Kanomax USA, Inc.
  • Page 12: Section 2 - Switch Functions

    Press the FPM/MPS key to switch the measurement units from FPM (feet per minute, 1 FPM resolution) to MPS (meters per second, 0.01 MPS resolution). 6824 ™ User Manual, PN 10283 Kanomax USA, Inc Rev 2.0, 1-Dec-2022 www.kanomax-usa.com Page 12 of 28 Copyright © 2022, Kanomax USA, Inc.
  • Page 13 MAX/MIN key was pressed, and the sample rate is set to 16 seconds. To exit MAX/MIN mode, press the SAMPLE RATE key. 6824 ™ User Manual, PN 10283 Kanomax USA, Inc Rev 2.0, 1-Dec-2022 www.kanomax-usa.com Page 13 of 28 Copyright © 2022, Kanomax USA, Inc.
  • Page 14: Appendix A - Lcd Display Symbols

    To return to MAX/MIN mode, press the HOLD/RESET key again. APPENDIX A – LCD DISPLAY SYMBOLS 6824 ™ User Manual, PN 10283 Kanomax USA, Inc Rev 2.0, 1-Dec-2022 www.kanomax-usa.com Page 14 of 28 Copyright © 2022, Kanomax USA, Inc.
  • Page 15: Appendix B - Battery Replacement

    Phone: 1-800-247-8887 PO Box 372 Fax: (973) 786-7586 Andover, NJ 07821 USA sales@kanomax-usa.com APPENDIX B – BATTERY REPLACEMENT 6824 ™ User Manual, PN 10283 Kanomax USA, Inc Rev 2.0, 1-Dec-2022 www.kanomax-usa.com Page 15 of 28 Copyright © 2022, Kanomax USA, Inc.
  • Page 16: Appendix C - Airflow Volume Calculations

    Step 3: Volume flow = Air Velocity x Area, therefore, Volume flow rate = 450 FPM x 2 sq ft. = 900 CFM. 6824 ™ User Manual, PN 10283 Kanomax USA, Inc Rev 2.0, 1-Dec-2022 www.kanomax-usa.com Page 16 of 28 Copyright © 2022, Kanomax USA, Inc.
  • Page 17: Appendix D - Analog Outputs (If Equipped)

    49.16 °C. ► 3.458 Volts 20 – 20 = 49.16 °C × 6824 ™ User Manual, PN 10283 Kanomax USA, Inc Rev 2.0, 1-Dec-2022 www.kanomax-usa.com Page 17 of 28 Copyright © 2022, Kanomax USA, Inc.
  • Page 18 ±2% of reading ±1 digit (±11 FPM). Custom Analog Voltage Outputs are also available – contact Kanomax for details. Analog Output circuit block diagram and connector pin assignment Mating Cable Connector: Binder Part No.
  • Page 19: Appendix E - Usb Data Output (If Equipped)

    For Windows users, open the Windows Device Manager (found in Control Panel) and verify that a USB serial port exists as shown below. 6824 ™ User Manual, PN 10283 Kanomax USA, Inc Rev 2.0, 1-Dec-2022 www.kanomax-usa.com Page 19 of 28 Copyright © 2022, Kanomax USA, Inc.
  • Page 20 NOTE: Units with USB or RS232 communications, output only Air data at this time. Temperature data is not available on the output. 6824 ™ User Manual, PN 10283 Kanomax USA, Inc Rev 2.0, 1-Dec-2022 www.kanomax-usa.com Page 20 of 28 Copyright © 2022, Kanomax USA, Inc.
  • Page 21: Appendix F - Rs232 Communications (If Equipped)

    You are now ready to capture the data being measured by your instrument. Please refer to Appendix G – Viewing and Capturing Data for further instructions. 6824 ™ User Manual, PN 10283 Kanomax USA, Inc Rev 2.0, 1-Dec-2022 www.kanomax-usa.com Page 21 of 28 Copyright © 2022, Kanomax USA, Inc.
  • Page 22: Appendix G - Viewing And Capturing Data

    There are many terminal emulator programs available on the market. It is up to the end-user to determine which program is compatible with his/her system, what settings it may require and the Kanomax product being used. Kanomax. does not endorse or recommend any of these programs and assumes no liability for their use.
  • Page 23 Set the ‘Baud Rate:’ to 9600 You will now receive data from your instrument. The graphic below shows the serial port output data from Parallax Serial Terminal when connected to a Kanomax 6824 Instrument. CFM was selected part way through. Graphics may vary. 6824 ™...
  • Page 24 Measurement Units Same as Units shown on LCD Display Below are examples of the formatted output data for Kanomax 681x Instruments (units may be different depending on the units selected on the LCD display): Model 6822 displaying in Air Velocity Mode:...
  • Page 25 Andover, NJ 07821 USA sales@kanomax-usa.com Exporting and Graphing Data Exporting serial port instrument data from the Kanomax instrument to a spreadsheet application such as Microsoft Excel or OpenOffice Calc allows the data to graphed or recorded. The simplest way to export the instrument data is to use a terminal emulator...
  • Page 26 219 Route 206 Phone: 1-800-247-8887 PO Box 372 Fax: (973) 786-7586 Andover, NJ 07821 USA sales@kanomax-usa.com Notes: 6824 ™ User Manual, PN 10283 Kanomax USA, Inc Rev 2.0, 1-Dec-2022 www.kanomax-usa.com Page 26 of 28 Copyright © 2022, Kanomax USA, Inc.
  • Page 27 Please contact us or visit our website for the latest information on calibrating your instrument. 6824 ™ User Manual, PN 10283 Kanomax USA, Inc Rev 2.0, 1-Dec-2022 www.kanomax-usa.com Page 27 of 28 Copyright © 2022, Kanomax USA, Inc.
  • Page 28 219 Route 206 PO Box 372 Andover, New Jersey 07821 (800) 247-8887 Fax: (973) 786-7586 sales@kanomax-usa.com www.kanomax-usa.com Copyright © 2022, Kanomax USA, Inc 6824 ™ User Manual, PN 10283 Kanomax USA, Inc Rev 2.0, 1-Dec-2022 www.kanomax-usa.com Page 28 of 28...