7.
HORIZONTAL DISCHARGE INSTALLATION (INTERNAL BLOWER(S) ONLY)
Slide the blower to disengage its flange from the retaining bracket.
Flip
the
blower
and
engage
its
flange
in the
back
wall
retaining
bracket.
Using
a
5/16"
socket
and
the
screws previously removed, secure
the blower to the hood.
Plug the blower in.
NOTE FOR DUAL BLOWER HOOD ONLY: Cut off the plastic tie wrap on left motor cable.
|
HEO08S
8.
INSTALL THE ADAPTER AND THE TRANSITION (IF NEED BE)
(INTERNAL BLOWER HOOD ONLY)
Using standard 3/8" screws provided,
;
secure the adapter to the top (or
:
back) of the hood (2 screws for a
eS
3%"
x
10"
adapter/damper
and
4 screws fora 4%" x 18%" adapter).
Seal the adapter to the hood using
duct tape. For round ducting, install
an appropriate sized transition and
seal the joints with duct tape.
HJ0013
9.
INSTALL ANKE60 RECIRCULATION KIT (NON DUCTED INSTALLATION ONLY)
Refer to the installation sheet included with the recirculation kit for details.