Supply Air Adjustments (Ecm Variable Speed Motors); Installation Of Accessories; Humidifier (Hum); Electronic Air Cleaner (Eac) - Bryant OBM112 Installation Instructions Manual

Multipoise oil furnace
Table of Contents

Advertisement

2.11 SUPPLY AIR ADJUSTMENTS
(ECM VARIABLE SPEED
MOTORS)
On units equipped with ECM variable speed blower mo-
tors, the air supply must be adjusted based on heating/air
Table 2 – Airflow adjustments heating mode
SW1-HEAT
DIP Switch Positions
1
2
OFF
OFF
ON
OFF
OFF
ON
ON
ON
*Alternate adjustments for both input rate (refer to air
flow tables)
Table 4 – Airflow adjustments heating mode
SW3-ADJ (Adjustment)
DIP Switch Positions
1
2
POSITION
OFF
OFF
A
ON
OFF
B
OFF
ON
C
ON
ON
D
2.12 INSTALLATION OF
ACCESSORIES
WARNING
E
LECTRICAL SHOCK HAZARD
Turn OFF electrical power at the fuse box or ser-
vice panel before making any electrical connec-
tions and ensure a proper ground connection is
made before connecting line voltage.
Failure to do so can result in death or bodily injury.
2.12.1 Humidifier (HUM)
The electronic board supplies 120 VAC for a humidifier
on the HUM terminal. It supplies 120 VAC electric power
INPUT
USGPH
POSITION
A
0.63
B
0.80
C*
0.68
D*
0.80
CFM HT G.
CFM A/G.
% Increase
% Increase
or decrease
or decrease
0%
0%
10%
10%
-10%
-10%
N/A
0%
.
conditioning output. The start/stop delays of the blower
must also be adjusted by positioning the DIP switches on
the electronic board.
Refer to the following tables, airflow tables and the wiring
diagram in this manual for the proper settings:
Table 3 – Airflow adjustments air conditioning
mode
SW2-COOL
DIP Switch Positions
1
OFF
ON
OFF
ON
Table 5 – Delay adjustments heating mode
SW4-Delay
DIP Switch Positions
1
OFF
ON
OFF
ON
when the burner is in operation.
A 24 VAC signal can also be supplied from the W and
C terminals on the blower electronic board to activate a
switching relay.
Also refer to the instructions supplied with the accessory.

2.12.2 Electronic Air Cleaner (EAC)

The EAC terminal on the electronic board supplies 120
VAC when the blower is operating in the heating or air
conditioning mode. This signal can be used to activate an
electronic air cleaner that is not equipped with an air flow
switch. If the cleaner is equipped with an air flow switch,
the S terminal on the PSC electronic board or one of the
120 VAC terminals on the ECM electronic board can be
used to provide a constant supply of 120 VAC.
Also refer to the instructions supplied with the accessory.
12
2
POSITION
OFF
A
OFF
B
ON
C
ON
D
2
POSITION
OFF
A
OFF
B
ON
C
ON
D
INPUT
USGPH
3.5
3.0
2.5
2.0
INPUT
USGPH
0.68
0.80
ALL
ALL