• The minimum approach distance may be reduced if insulating
barriers are installed to prevent contact, and the barriers are
rated for the voltage of the line being guarded. These barriers
shall not be part of (or attached to) the machine. The mini-
mum approach distance shall be reduced to a distance within
the designed working dimensions of the insulating barrier.
This determination shall be made by a qualified person in
accordance with the employer, local, or governmental require-
ments for work practices near energized equipment.
DO NOT MANEUVER MACHINE OR PERSONNEL INSIDE PROHIBITED ZONE (MAD).
ASSUME ALL ELECTRICAL PARTS AND WIRING ARE ENERGIZED UNLESS KNOWN
OTHERWISE.
31215018
SECTION 1 - SAFETY PRECAUTIONS

Tipping Hazards

• Ensure that the ground conditions are adequate to support
the maximum load indicated on the load decals located on the
chassis adjacent to each track. Do not travel on unsupported
surfaces.
• The user must be familiar with the operating surface before
driving. Do not exceed the allowable sideslope and grade
while driving.
• Do not elevate platform or drive with platform elevated while
on or near a sloping, uneven, or soft surface. Ensure machine is
positioned on a smooth, firm surface within the limits of the
maximum operating slope before elevating platform or
driving with the platform in the elevated position.