Section E; Routine Maintenance; Inspection And Maintenance; Inspection And Maintenance Items - Toyotomi Oil Miser OM-180 Operation & Maintenance Instructions Manual

Instantaneous oil-fired water heater
Hide thumbs Also See for Oil Miser OM-180:
Table of Contents

Advertisement

SECTION E:

ROUTINE MAINTENANCE

WARNING: RISK OF INJURY FROM MOVING PARTS AND ELECTRICAL SHOCK.
RISK OF INJURY FROM MOVING PARTS AND ELECTRICAL SHOCK. Disconnect the power sup
ply cord before inspecting and servicing unit.All repairs should be left to professionals. RISK OF
BACKFIRE AND INDOOR POLLUTION. Before operation make sure the flue pipe is free of snow,
icing, leaves, bird's nest or strong drafts.
CAUTION:
RISK OF BURN INJURY. Do not touch the flue pipe top and the exhaust pipe.
Annual maintenance is recommended for most efficient operation.
When inspecting, ALWAYS do the following.
a. Press the Power Switch to OFF position.
b. Disconnect the power plug from the receptacle.
c. Close the fuel feed valve.
When inspecting, NEVER do the following.
a. Do not remove the thermistor.
b. Do not adjust the pressure of the fuel pump.

INSPECTION AND MAINTENANCE ITEMS

1.
FLAMMABLE IN THE ENVIRONMENT (REGULARLY)
Remove all flammable material from the area.
2.
FUEL LEAKS (REGULARLY)
Always check for oil leaks. Clean off spilled fuel thoroughly. If a leak is found, shut down the unit until
the problem is corrected.
3.
FUEL FEED LINE INSPECTION (REGULARLY)
Check for fuel leaks from the fuel feed line. Replace it if any cracks or leaks are found.
4.
WATER LEAKS (REGULARLY)
Check the heat exchanger for water leaks. Always correct if found.
5.
ODOR OR SOOT (REGULARLY)
If you notice soot at exhaust pipe fittings, exhaust gas may be leaking from the pipe joints. Consult your
dealer.
6.
DUST (ONCE A MONTH)
Check for dust inside of the unit and the bottom (base).
7.
WATER INSIDE THE FUEL TANK (ONCE A MONTH)
Remove any water or waste particles that accumulate inside the fuel tank.
8.
FUEL STRAINER / FUEL FILTER (ONCE A MONTH)
Vibration, noise, ignition and combustion failure could be caused by water or waste particles in the fuel
strainer and the fuel filter. Clean the strainer and filter once a month.
9.
FLUE PIPE (ONCE A MONTH)
A clogged flue pipe will cause improper combustion.
Inspection for any clogging or soot accumulation should
be done at least once every year. Make sure not to place
combustibles in the flue pipe area.
Make sure that exhaust gas is not leaking from the flue pipe.
Also check whether there are leaks from pipe joints.

INSPECTION AND MAINTENANCE