POWER SAVER OPERATION

The Power Saver mode reduces the frequency of ignition actions, to save electric consumption.
Press the POWER SAVER button "ON" to start the operation of the "POWER SAVER".
When the room temperature exceeds the selected setting by approximately 10°F, the heater will automatical-
ly shut off. As the room temperature becomes lower than the selected setting, the heater will automatically
re-start to maintain the desired temperature.
Approx. +10˚F
Approx. +1˚F

TIMER OPERATION

"TIMER" operation is programmed for particular time of hour and temperature, in order to save energy
when the heater is used at night or while you leave home.
NOTE: The Laser 30 has a dual timer feature (this is not an automatic setback).
The timer feature allows a user to manually lower the temperature (set by user) until a certain time of day
(set by user) by pressing a timer button. This button must be pushed each time you want the temperature to
drop back. It is not automatic. There are two timer buttons on the Laser 30, 1st timer and 2nd timer. This
allows for two different temperature drop backs per 24 hour period.
Example 1st Timer:
Your normal room temperature is set for 70 degrees. You
work from 8 am until 5 pm. You want the room temperature to
drop to 62 degrees while you are at work and you want the
room to return to 70 degrees at 4 pm so it will be warm when
you get home. When you leave for work you must press the
1st timer button to activate the timer. The temperature will
drop to 62 degrees and return to 70 degrees at 4 pm.
Example 2nd Timer:
Your normal room temperature is set of 70 degrees. When
you go to bed, you want the temperature to drop to 65
degrees. You get up at 6 am and want the room warm
when you get up. When you go to bed, you must push the
2nd timer button to activate timer. The temperature will
drop to 65 degrees and stay there until the time at which
you set (5:00 am) the until to return to normal temperature.
SET
TEMP.
High
Medium
Low
Off
Re-lgnition
70°F
(Ordinary set temp.)
62˚F
Press
"1st" Timer button
Set
70˚F
70˚F
Temp.
62˚F
4:00PM
Press "1st" Timer
Press "2nd" Timer
button. (7:00AM)
button. (11:00PM)
70°F
(Ordinary set temp)
4:00PM
70˚F
65˚F
5:00AM
10