Alert Category: System - Other
SNMP Trap ID:
CIM Prefix: PLAT CIM ID: 0108
User Action:
Information only; no action is required
• FQXSPPW0031J: Numeric sensor [NumericSensorElementName] going low (lower non-critical) has
asserted.
This message is for the use case when an implementation has detected a Lower Non-critical sensor going
low has asserted.
Severity: Warning
Serviceable: Yes
Automatically notify Support: No
Alert Category: Warning - Voltage
SNMP Trap ID: 13
CIM Prefix: PLAT CIM ID: 0476
User Action:
CMOS battery is recommended to replace with new one.
• FQXSPPW0035M: Numeric sensor [NumericSensorElementName] going low (lower critical) has
asserted.
This message is for the use case when an implementation has detected a Lower Critical sensor going low
has asserted.
Severity: Error
Serviceable: Yes
Automatically notify Support: Yes
Alert Category: Critical - Voltage
SNMP Trap ID: 1
CIM Prefix: PLAT CIM ID: 0480
User Action:
Complete the following steps:
1. If the specified sensor is Planar 3.3V or Planar 5V, (trained technician only)replace the system board.
2. If the specified sensor is Planar 12V, ensure PDB board is installed correcly and check the XClarity
Controller event log for power-supply-related issues, and resolve those issues.
3. If the problem remains, replace (trained technician only)
4. If system has stand-by power, please collect Service Data log.
5. Contact Lenovo Support.
• FQXSPPW0057J: Sensor [SensorElementName] has transitioned from normal to non-critical state.
This message is for the use case when an implementation has detected a Sensor transitioned to non-
critical from normal.
Severity: Warning
Serviceable: Yes
Automatically notify Support: No
Alert Category: Warning - Power
SNMP Trap ID: 164
CIM Prefix: PLAT CIM ID: 0520
92
ThinkSystem SD665-N V3 Messages and Codes Reference