User Action:
Check if system have fan fail error, Raidlink CEM fail occurring or Ambient temperature over 35C,
implement the "error" service action to recovery the system and reduce ambient temperature under 35C.
• FQXSPSD0000I: The [StorageVolumeElementName] has been added.
This message is for the use case when an implementation has detected a Drive has been Added.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID: 22
CIM Prefix: PLAT CIM ID: 0162
User Action:
Information only; no action is required
• FQXSPSD0001I: The [StorageVolumeElementName] Drive [arg1] in the enclosure/chassis(MTM-
SN: [arg2]) has been added.
This message is for the use case when an implementation has detected a Drive has been Added.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID: 22
CIM Prefix: PLAT CIM ID: 0162
User Action:
Information only; no action is required
• FQXSPSD0001L: The [StorageVolumeElementName] has a fault.
This message is for the use case when an implementation has detected a Drive was Disabled due to fault.
Severity: Error
Serviceable: Yes
Automatically notify Support: Yes
Alert Category: Critical - Hard Disk drive
SNMP Trap ID: 5
CIM Prefix: PLAT CIM ID: 0164
User Action:
Complete the following steps:
1. Make sure that the reported device is compatible by checking https://static.lenovo.com/us/en/
serverproven/index.shtml.
2. Collect the service data log from the management controller interface and contact Lenovo Support.
• FQXSPSD0002G: Failure Predicted on [StorageVolumeElementName] for array
[ComputerSystemElementName].
This message is for the use case when an implementation has detected an Array Failure is Predicted.
Severity: Warning
Serviceable: Yes
Automatically notify Support: Yes
.
Chapter 2
XClarity Controller events
97