Installation and connection
Electrical connection
The appliance must be connected to the mains by a licensed
expert. The regulations of your electricity supplier must be
observed.
Any damage arising from the appliance being connected
incorrectly will invalidate the guarantee.
For the installer
An all-pole isolating switch with a contact gap of at least
■
3 mm must be present in the installation circuit. This is not
necessary if the appliance is connected by a plug that is
accessible to the user.
Electrical safety: The cooker corresponds to safety class I
■
and may only be used in conjunction with a safety earth
terminal.
A type H 05 VV-F or equally rated lead must be used to
■
connect the appliance.
Wall fixing
To prevent the cooker from tipping over, you must fix it to the
wall using the enclosed bracket. Please observe the installation
instructions for fixing the oven to the wall.
Door lock
To prevent children from being able to reach into the oven
when it is hot, the oven door is equipped with a lock. It is
located at the top of the oven door.
Opening the oven door
Press the lock upwards (picture A).
Removing the door lock
If the door safety lock is no longer needed or if it is soiled:
Opening the oven door
1.
Unscrew the screw and remove the door lock (picture B).
2.
Close the oven door.
3.
7