Note: Make sure to seal these edges as any
missed spots or leakages will affect overall
performance of dust collector.
41. Place collection drum vacuum ring on bottom
of collection drum assembly once sealant is
dry.
Note: During operation, this ring and vacuum
connection to cyclone funnel will prevent col-
lection bag from collapsing.
42. Install larger plastic collection bag into drum.
43. Apply (2) 5 x 50 x 2000mm foam tape rolls to
inside rim of drum lid to create a seal when
placed on drum.
44. Place collection drum lid on top of collection
drum (see Figure 33).
Collection
Drum
Figure 33. Drum lid placed on collection drum.
45. Position cyclone funnel adapter and drum
lid together with (2)
drum lid springs, and (4)
shown in Figure 34.
x 2
Drum Lid
Spring
Figure 34. Installing cyclone funnel adapter.
Model G0638HEP (Mfd. Since 7/20)
Drum Lid
"-16 x 11" hex bolts, (2)
3
8
" flat washers, as
3
8
Cyclone Funnel
Adapter
46. Install drum lid connecting plates with (2)
16 x 1" hex bolts, (4)
"-16 lock nuts (see Figure 35).
3
8
Figure 35. Installing drum lid connecting plates
on drum lid.
47. Attach collection lid handle to cyclone funnel
adapter and drum lid connecting plates with
(4)
"-16 x 1" hex bolts, (8)
3
8
"-16 lock nuts (see Figure 36).
and (4)
3
8
Drum Lid
Connecting Plate
Handle
(1 of 2)
Figure 36. Collection lid handle attached to
connecting plate and adapter.
48. While holding assembly in place, move col-
lection drum assembly under cyclone assem-
bly. Press cyclone funnel adapter and springs
down to fit under small cyclone funnel.
"-
3
8
" flat washers, and (2)
3
8
Connecting Plate
(1 of 2)
x 2
" flat washers,
3
8
Cyclone
Funnel
x 4
Adapter
-13-