Appliance
dimensions
103¼"
(273 mm)
<
715_6"
(201.6 mm)
A
30"
(762 mm)
5 II
(126 mm)
A
Ductless (recirculating)
version only:
*Max 42 5/8" (1083 mm)
*Min 28 5/16" (719 mm)
Ducted version only:
*Max 38 11/16" (983 mm)
*Min 24 5/8" (625 mm)
Safety
clearances
_,
WARNING
RISK OF FIRE
Grease deposits
in the grease filter can catch fire.
The given safety clearance must be observed to
avoid heat buildup. Observe the specifications
for
your cooking appliance,
tf gas and electric cooktops
are used together, the largest given clearance
applies.
The appliance
may only be installed directly next to
a cabinet or wall on one side. The wall or cabinet
clearance must be at least 2" (50 mm).
The clearance between the shelf on the cooktop and the
bottom of the extractor hood may not be less than 24"
(610 mm) in the case of electric cooktops and 30"
(760 mm) in case of gas or combined
ranges.
If the installation
instructions for the gas cooking
appliance
specify a larger distance, this must be taken
into account.
Electrical cooktop
min. 24" (610 mm)
Gas cooktop
min. 30" (760 mm)
Fan operation
Note:
Ventilation may not exit through an already
operational
smoke or exhaust chimney, nor a duct used
for ventilating furnace installation areas.
o If the ventilation is intended to pass through a smoke
or exhaust that is not in operation, the responsible
area heating inspector must give approval.
o If the ventilation passes through an external wall, use a
telescope
wall sleeve.
Ventilation
line
Note:
The device manufacturer
does not assume any
warranty for complaints
attributable
to the pipe section.
o The ventilation opening and the exhaust air ducts must
be made according to the local circumstances.
o The device achieves its optimum performance
by
means of a short, straight exhaust air pipe and as
large a pipe diameter as possible.
o As a result of long rough exhaust air pipes, many pipe
bends or too-small diameters, the optimum
extraction
performance
is not achieved and fan noise is
increased.
The pipes or hoses for laying the exhaust air line must
consist of non-combustible
material.
Smooth the connection
area of the pipes before
installation.
Seal the connection
points of the pipes appropriately.
10