Refrigeration Charge - Follett Horizon Elite 1400 Series Operation And Service Manual

Hide thumbs Also See for Horizon Elite 1400 Series:
Table of Contents

Advertisement

Refrigeration system diagram
CONDENSER UNIT
CONDENSER
HEAD CONTROL VALVE
EVAPORATOR UNIT
SOLENOID VALVE
THERMOSTATIC
EXPANSION
VALVE

Refrigeration charge

All service on refrigeration systems must be performed in accordance with all federal, state and local laws. It is the
responsibility of the technician to ensure that these requirements are met. Recharging ice machine to other than
factory specifications will void the warranty.
Line Run
0 - 100' (0 - 30.5 m)
100' + (30.5 m+)
Note: Condensing unit shipped with 0.5 lb R404A charge.
34
COMPRESSOR
CHECK VALVE
HIGH PRESSURE SWITCH
CHECK VALVE
HEAT EXCHANGER
SERVICE PORT
FILTER
SIGHT GLASS
R404A Ice Machine Charge Specifications
Total Charge 1010/1410 (Tecumseh)
12.5 lb (5.7 kg)
not recommended – consult factory
HIGH SIDE
SERVICE VALVE
W/ SERVICE PORT
HIGH SIDE
HIGH SIDE
SERVICE PORT
HIGH SIDE
COUPLING
LOW SIDE
COUPLING
LOW SIDE
LOW SIDE
PORT
PORT
Total Charge 1410R three phase
HCD1010R/N, HMF1010R/N, HCD1410R/N, HMF1410R/N
SUCTION
ACCUMULATOR
RECEIVER
FILTER-DRIER
SIGHT GLASS
HIGH SIDE
SERVICE VALVE
W/ SERVICE PORT
LOW SIDE
SERVICE VALVE
W/ SERVICE PORT
(Larkin)
10 lb (4.5 kg)