WIRING DIAGRAMS
BR
PU
BR
CM
YL
BK
RD
S
C R
COMP
CH & CHS OPTIONAL
@ L1,L2, SEE NOTE 6
BK
BK
COM PONENT LEGEND
CONTACTOR
C
CRANKCASE HEATER
CH
CHS
CRANKCASE HEATER SWITCH
CM
CONDENSER MOTOR
COMP
COMPRESSOR
EM
EVAPORATOR MOTOR
EQUIPMENT GROUND
GND
HIGH PRESSURE SWITCH
HPS
LOW VOLTAGE JUNCTION BOX
LVJB
LVTB
LOW VOLTAGE TERMINAL BLOCK
PLF-C
FEMALE PLUG / CONNECTOR-CONTROL
PLF-H
FEMALE PLUG/CONNECTOR-HEAT KIT
PLF-P
FEMALE PLUG/ CONNECTOR- PRESSURE SWITCH
PLM-B
MALE PLUG/ CONNECTION BLOWER
PLM-P
MALE PLUG/ CONNECTOR- PRESSURE SWITCH
RUN CAPACITOR FOR
RCCF
COMPRESSOR AND FAN
START ASSIST
SA
TR
TRANSFORMER
FACTOR Y WIRING
LINE VOLTAGE
LOW VOLTAGE
OPTIONAL HIGH
VOLTAGE
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
BK
PLM-P
2
2
YL
1
1
YL
PLF-P
HPS
PU
BK
GR
C
L G N
SEE NOTE 2
1
2
3
4 5
EM
GR
WIRE COD E
BK
BLACK
BL
BLUE
BR
BROWN
GR
GREEN
OR
ORANGE
PURPLE
PU
RD
RED
WH
WHITE
YL
YELLOW
BL/PNK
BLUE/PINK STRIPE
FI E LD WIRING
HIGH VOLTAGE
LOW VOLTAGE
YL
BK
RD
BK
BK
PU
SEE
1
2
3
NOTE 3
C
208
240
GR
TR
YL
24V
BL
YL
YL
RD
BL
RCCF
H
F
YL
C
SA
SEE NOTE 4
BL
BK
BL
BL
WH
WH
PU
BK
YL
GR
PLF-C
PU
BK
PLM-B
BL
YL
WH
NOTES :
1. REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE IN
AS ORIGINAL (AT LEAST 105˚ C ) USE COPPER COND
2. TO CHANGE EVAPORATOR MOTOR SPEED MOVE YELLOW
WHITE LEADS FROM EM"2" AND "3" TO "4" AND "5"
ARE ENERGIZED, THE HIGHER SPEED SETTING IS U
3. FOR 208 VOLT TRANSFORMER OPERATION MOVE BLACK
FROM TERMINAL 3 TO TERMINAL 2 ON TRANSFORMER.
4. START ASSIST FACTOR EQUIPPED WHEN REQUIRED
5. USE COPPER CONDUCTORS ONLY
USE N.E.C. CLASS 2 WIRE
6. CRANKCASE HEATER (OPTIONAL)
7. DOUBLE POLE CONTACTOR SHOWN. SINGLE POLE CONT
COULD BE FACTORY EQUIPPED AS AN ALTERNATE CON
SEE UNIT RATING PLATE FOR TYPE AND SIZE
OF OVER CURRENT PROTECTION
208-230/1/60 0140G03217-C
PU
RD
T2
RD
BK
BK
T1
SEE NOTE 7
YL
BL
YL
YL
BL
LVTB
WH
WH
L1
WH
3
6
9
BR
2
5
8
1
4
7
C
PLF-H
BL
SEE
NOTE #7
SULATION
UCTOR ONLY.
AND
. IF BOTH LEADS
SED.
WIRE
ACTOR
FIGURATION.
PLF
0140G03217-C
GPCM3[24-60]M41A*
PU
BK
L2
SEE NOTE 1
C
208-230/1/60
L1
GND
LVJB
YL
Y
RD
R
BL
C
THERMOSTAT
WH
W1
BR
W2
GR
G
SEE
NOTE 5
CONTROL
BOX
L2
SUPPLY VOLTAGE
208-230/1/60
SEE NOTE 1
CH
CHS
SEE NOTE 6
T2
C
R
T1
C COMP
C
S
RCCF
H
F
S.A.
CM
IF USED
SEE NOTE #4
NOTE #2
N
L
EM
3
G
1
2
208-230
NOTE #3
2
3
1
TR
24V
2
3
1 EM
C
4
SEE NOTE #2
5
C
6
HPS
W1
Y
G
C
R
W2
THERMOSTAT