36" FULL GAS RANGE INSTALLATION INSTRUCTIONS
This ID plate must never be removed.
Gas safety
WARNING
Burning gas cooking fuel gener-
ates some by-products which are on the list of sub-
stances which are known by the State of California
to cause cancer or reproductive harm. To minimize
exposure to these substances, always operate this
unit according to the instructions contained in this
booklet and provide good ventilation.
Install a gas shutoff valve near the appliance. It must
be easily accessible in an emergency.
Leak testing must be conducted by the installer
according to the instructions in this manual. The
appliance and its individual shutoff valve must be
disconnected from the gas supply piping system
during any pressure testing at pressures in excess
of ½ psi (3.5 kPa).
The appliance must be isolated from the gas supply
piping system by turning off its individual manual
shutoff valve during any pressure testing of the gas
supply piping system at test pressures equal to or
less than ½ psi (3.5 kPa). The minimum supply pres-
sure must be 1" water column above the manifold
pressure printed on the rating label. The maximum
supply pressure of 14.0 inches water column (34.9
Millibars) must not exceed.
IMPORTANT SAFETY NOTICE: Burning gas cook-
ing fuel generates some by-products which are on
the list of substances which are known by the State
of California to cause cancer or reproductive harm.
To minimize exposure to these substances, always
operate this unit according to the instructions con-
tained in this booklet and provide good ventilation.
WARNING
State of California Proposi-
tion 65 Warning:
This product may contain a chemical known to
the State of California, which can cause can-
cer or reproductive harm. Therefore, the pack-
aging of your product may bear the following
label as required by California. For more infor-
mation go to www.P65Warnings.ca.gov
Propane gas installation
The propane gas tank must be equipped with its
own high pressure regulator. In addition, the regula-
tor supplied with this unit must also be used. The
appliance is shipped from the factory for use with
natural gas. It must be converted for use with pro-
pane. The conversion must be done by a qualified
technician or installer. This appliance has been certi-
fied for safe operation up to a height of 10,000 ft.
Exception: To use it with propane gas, the appliance
must be converted in accordance with the propane
conversion instructions.
For Massachusetts installations:
• Installation must be performed by a qualified or
licensed contractor, plumber or gas fitter qualified
or licensed by the state, province or region where
this appliance is being installed.
• Shut-off valve must be a "T" handle gas cock.
• Flexible gas connector must not be longer than
36 inches.
Installer - show the owner where the gas shut-off
valve is located.
Gas connection
The appliance is shipped from the factory for use
with natural gas at a pressure of 5" of water column.
When checking if the regulator is working properly,
the inlet pressure must be at least 1" greater than
the operating (manifold) pressure above. When
used with natural gas, the pressure supplied to the
regulator must be between 6" and 10.5" of the water
column.
10