PROBlEm
TEMPERATURES ARE TOO WARM
freezer/fresh food tem-
perature is too warm.
freezer temperature is
too warm. fresh food
temperature is satisfac-
tory.
fresh food temperature
is too warm. freezer tem-
perature is satisfactory.
Temperature in the meat
Keeper is too warm
(some models).
WATER/MOISTURE/FROST INSIDE REFRIGERATOR
moisture collects on
inside of refrigerator
walls.
Water collects on bot-
tom side of drawer
cover.
Water collects in bottom
of drawer.
WATER/MOISTURE/FROST OUTSIDE REFRIGERATOR
moisture collects on
outside of refrigerator
or between doors.
AUTOMATIC ICE MAKER
Ice maker is not making
any ice.
BEfORE yOU CAll (CONTINUED)
CAUSE
•
Doors are opened too frequent-
ly or too long.
•
Door is slightly open.
•
Condenser is dirty.
•
Freezer control is set too warm.
•
Fresh Food control is set too
warm.
•
Meat Keeper temperature con-
trol is set too warm.
•
Weather is hot and humid.
•
Door is slightly open.
•
Door is opened too often or too
long.
•
Open containers.
•
Vegetables contain and give off
moisture.
•
Washed vegetables and fruit
drain while in the drawer.
•
Weather is humid.
•
Door is slightly open, causing
cold air from inside refrigerator
to meet warm air from outside.
•
Ice maker wire signal arm is in
the "up" or Off position.
•
Ice maker power switch is Off.
•
Household water line valve is
not open.
•
Ice maker has small cube
caught in mechanism.
•
Freezer is not cold enough.
•
Saddle valve on cold water
pipe is clogged or restricted by
foreign material.
CORRECTION
•
Warm air enters the refrigerator whenever the door is
opened. Open the door less often.
PROBlEm column OPENING/CLOSING OF
•
See
DOORS/DRAWERS.
•
Clean condenser. See
& ClEANINg section.
•
Set freezer control to a colder setting. Allow 24 hours for
temperature to stabilize.
•
Set Fresh Food control to a colder setting. Allow 24
hours for temperature to stabilize.
•
Adjust Meat Keeper Temperature Control to a colder set-
ting.
•
The rate of frost buildup and internal sweating increases.
PROBlEm column OPENING/CLOSING OF
•
See
DOORS/DRAWERS.
•
Open door less often.
•
Keep containers covered.
•
It is not unusual to have moisture on the bottom side of
the cover.
•
Move humidity control (some models) to lower setting.
•
Dry items before putting them in the drawer. Water col-
lecting in bottom of drawer is normal.
•
This is normal in humid weather. When humidity is lower,
the moisture should disappear.
PROBlEm column OPENING/CLOSING OF
•
See
DOORS/DRAWERS.
•
Move wire signal arm to the "down" or
mounted)
•
Turn power switch to On ("
•
Turn on household water line valve.
•
Remove small cube from ice maker. The ice and water
filter cartridge may be clogged. Replace filter cartridge.
PROBlEm column TEMPERATURES ARE TOO
•
See
WARM.
•
Turn off household water line valve. Remove valve. En-
sure that valve is not a self-piercing saddle valve. Clean
valve. Replace valve if necessary.
14
Care & Cleaning Chart in CARE
ON position. (side