Siemens LC 5KDK6K Series User Manual And Installation Instructions page 27

Table of Contents

Advertisement

Available languages

Available languages

¡ Ensure that the protection against contact is guaran-
teed during installation.
13.6 Information on the installation situation
¡ Install this appliance on the kitchen wall.
¡ To install additional special accessory parts, ob-
serve the enclosed installation instructions.
¡ The appliance must be installed with no more than
one side directly next to a tall unit, an upper cabinet
or a wall. The distance between the appliance and
the tall cabinet, upper cabinet or the wall must be at
least 50 mm.
¡ The width of the extractor hood must correspond at
least with the width of the hob.
¡ To optimally detect the cooking vapours, install the
appliance in the middle of the hob.
13.7 Instructions for the exhaust air pipe
The appliance manufacturer does not provide any war-
ranty for faults attributable to the pipeline.
¡ Use a short, straight exhaust air pipe with as large a
pipe diameter as possible.
¡ Long, rough exhaust air pipes, many pipe bends or
small pipe diameters reduce the suction power and
increase the fan noise.
¡ Use an exhaust pipe that is made of non-combust-
ible material.
¡ To prevent condensate from returning, fit the ex-
haust pipe with a 1° gradient from the appliance.
Flat ducts
Use flat ducts with an inner cross-section that corres-
ponds to the diameter of the round pipes:
¡ Diameter of 150 mm corresponds to ap-
prox. 177 cm².
¡ Diameter of 120 mm corresponds to ap-
prox. 113 cm².
¡ Use sealing strips for different pipe diameters.
¡ Do not use any flat ducts with sharp bends.
Round pipes
Use round pipes with an inner diameter of 150 mm (re-
commended) or at least 120 mm.
13.8 Instructions for the air extraction mode
For air extraction mode, a one-way flap should be in-
stalled.
Notes
¡ If a one-way flap is not included with the appliance,
one can be ordered from a specialist retailer.
¡ If the exhaust air is conveyed through the external
wall, a telescopic duct should be used.
13.9 Information about circulating-air mode
The appliance must only be operated when it is se-
curely installed and the pipework is connected.
13.10 General information
Follow these general instructions during the installation.
¡ For the installation, observe the currently valid build-
ing regulations and the regulations of the local elec-
tricity and gas suppliers.
¡ When discharging the exhaust air, the official and
legal regulations, such as the regional building
code., must be observed.
¡ In order to freely access the appliance for servicing,
select an easy-to-reach installation site.
¡ The surfaces of the appliance are sensitive. Avoid
damaging them during installation.
13.11 Installation
Checking the wall
Check whether the wall is vertical and has sufficient
1.
load-bearing capacity.
The maximum weight of the appliance is 12 kg.
Drill the hole depth in accordance with the length of
2.
the screws.
The wall plugs must have a secure grip.
The enclosed screws and wall plugs are suitable for
securing the appliance to the following walls: Solid
brickwork, plasterboard, porous concrete, poroton
bricks.
Preparing the wall
Ensure that there are no electrical wires, gas pipes
1.
or water pipes in the area where holes are to be
drilled.
Cover the hob to prevent damage.
2.
Mark a vertical centre line on the wall from the ceil-
3.
ing to the lower edge of the appliance.
Remove the drilling template from the accessories
4.
bag.
Using the drilling template, measure and mark the
5.
positions of the fastening screws.
The bottom edge of the appliance is identical to the
lower edge of the drilling template.
Drill the holes.
6.
Insert the wall plugs flush with the wall.
7.
Screw in the screws for the appliance bracket
8.
loosely; do not tighten them fully.
Installation instructions en
27

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lc 5kdk 0 seriesLc85kdk60

Table of Contents