Testing; System Alarms - ADC H4TU-C-231-L5A User Manual

Table of Contents

Advertisement

LTPH-UM-1253-01
T
ESTING
This section provides information about system alarms, LOS and AIS response, OCT55 test procedure, and
loopback testing.
S
A
YSTEM
LARMS
Table 16
provides a summary of the system alarms displayed on the H4TU-C, H4D doubler, and H4TU-R alarm
history screens (see
"Using the Performance Screens to View Alarm Data" on page
Message on Screen
Alarm
SH0RT
Power Feed Short
GND
Power Feed Ground
OPEN
Power Feed Open
LOSW-LP1 or
Loop(n)-Loss of Sync Word HDSL4 Loop 1 or Loop 2 has lost synchronization.
LOSW-LP2
LLOS
Line (Unit) Loss of Signal
RLOS
Remote (Unit) Loss of
Signal
LAIS
Line Alarm Indication Signal Indicates an AIS (unframed all ones) pattern is
RAIS
Remote Alarm Indication
Signal
LRAI
Line RAI—Remote Alarm
Indication at the H4TU-R
(Net signal does not have
errors.)
RRAI
Remote RAI—Remote
Alarm Indication at the
H4TU-R (Net signal has
errors.)
TX RAI-CI
Transmit RAI-CI—Remote
Alarm Indication at the
H4TU-R
DBER
DS1 Bit Error Rate
LOF
Loss of Frame
H4TU-C-231 List 5AA
Table 16. System Alarms Displayed on Alarm History Screens
Description
A short exists between HDSL4 Loop 1 and
Loop 2.
One of the HDSL4 loops is grounded.
A line power open condition exists.
The span closest to the network has highest
priority.
Loss of the DSX-1 input signal at the H4TU-C.
Loss of the DS1 input signal at the H4TU-R.
being received at the H4TU-C DS1 input port.
Indicates an AIS (unframed all ones) pattern is
being received at the H4TU-R DS1 input port.
Indicates an RAI alarm (yellow) from the CPE with
an error-free signal from the line unit or network.
RAI signal is transmitted towards the network.
Indicates an RAI alarm (yellow) from the CPE with
errors from the line unit or network.
Upon reception of an RAI (yellow) from the CPE,
the H4TU-R sends an RAI-CI toward the network if
the network signal received at the H4TU-R is clear.
If the network signal is impaired (LOS, AIS, or
LOF), then the RAI is passed on to the network
unaltered.
The DS1 BER has exceeded the set 24-hour
threshold limit of approximately 10
The DS1 input does not contain the ESF or SF
frame pattern setting of the FRMG option.
October 15, 2003
30).
To Enable:
Always enabled.
Always enabled.
Always enabled.
Always enabled.
Always enabled.
Always enabled.
Always enabled.
Always enabled.
Select DIS for the RACI
option.
Always enabled.
Select ENA for the
RACI option.
Select ENA for the
-6
DBER system option.
Change FRMG option
to SF or ESF.

Testing

Continued
39