ADC H4TU-C-231-L5A User Manual page 24

Table of Contents

Advertisement

Provisioning
Table 5. H4TU-C Standard Config Menu Options (Continued)
Standard Config Menu
Options
Network Loopback Pattern
(NLBP)
Power Back Off - Network
(PBON)
See
"Power Back Off
Customer (PBOC) and Power
Back Off Network (PBON)
Options" on page
17.
Power Back Off - Customer
(PBOC)
See
"Power Back Off
Customer (PBOC) and Power
Back Off Network (PBON)
Options" on page
17.
ADC Config
Menu Options
Line Power Feed (PWRF)
Remote Provisioning (RTPV)
Bipolar Violation
Transparency (BPVT)
See
"Bipolar Violation
Transparency (BPVT) Option"
on page
17.
DS1 BER (DBER)
See
"DS1 BER (DBER)
Option" on page
18.
HDSL4 BER Threshold
(HBER)
See
"HDSL4 BER Threshold
(HBER) Option" on page
18.
SmartJack Loopback (LPBK)
16
Selection
Description
AIS
Enables the H4TU-R to transmit an AIS toward CI for any network loopback. For
priority resolution, see
LOS
Enables the H4TU-R to transmit an LOS toward CI for any network loopback.
DEF
Configures the power output levels of the H4TU-C network unit toward the customer
to comply with the Default template as defined in Section 6.1.4.2 of ANSI T1.418.
ENH
Configures the power output levels of the H4TU-C network unit toward the customer
to comply with the Enhanced template as defined in Section 6.1.4.2 of ANSI T1.418.
DEF
Configures the power output levels of the H4TU-R customer unit toward the network
to comply with the Default template as defined in Section 6.1.4.2 of ANSI T1.418.
ENH
Configures the power output levels of the H4TU-R customer unit toward the network
to comply with the Enhanced template as defined in Section 6.1.4.2 of ANSI T1.418.
Table 6. H4TU-C ADC Config Menu Options
Selection
Description
OFF
Disables powering to the HDSL4 pair.
ON
Enables HDSL4 line power.
ENA
Enables provisioning at the H4TU-R remote unit
DIS
Disables provisioning at the H4TU-R remote unit
ENA
Enables HDSL4 CRC and BPV errors at the DS1 input to be converted into DS1 BPVs
at the DS1 output at the distant end. This makes HDSL4 transparent to BPVs.
DIS
Disables BPV Transparency.
ENA
1E-3, 1E-4, 1E-5, 1E-6, 1E-7, 1E-8, or 1E-9 = alarm activates when the DSX-1 BER
alarm threshold exceeds the selected threshold.
DIS
Prevents the generation of a system alarm due to DS1 BER.
1E-6
Front-panel alarm is displayed and the Status LED flashes red when the Block Error
Rate (BER) threshold exceeds 10
1E-7
Front-panel alarm is displayed and the Status LED flashes red when the Block Error
Rate (BER) threshold exceeds 10
1E-8
Front-panel alarm is displayed and the Status LED flashes red when the Block Error
Rate (BER) threshold exceeds 10
1E-9
Front-panel alarm is displayed and the Status LED flashes red when the Block Error
Rate (BER) threshold exceeds 10
DIS
Prevents generation of a system alarm due to BER.
ENA
Enables the HDSL4 system to recognize all inband SmartJack (SMJK) loopback
commands.
DIS
Configures the HDSL4 system to ignore all inband SmartJack loopback commands.
October 15, 2003
Figure 26 on page
41.
When ON, the output voltage is set at -185V.
-6
. BER is based on the definition of Bit Error Rate.
-7
.
-8
-9
LTPH-UM-1253-01
Continued
H4TU-C-231 List 5A