[ III Specfications ]
Model
Power source
Cooling capacity
*1
(Nominal)
*1
Power input
Current input
Heating capacity
*2
(Nominal)
*2
Power input
Current input
External finish
External dimension H x W x D
Net weight
Heat exchanger
FAN
Type x Quantity
External
static press
Motor type
Motor output
Driving mechanism
Airflow rate
(Low-Mid-High)
Sound pressure level
(Low-Mid-High)
(measured in anechoic room)
Insulation material
Air filter
Protection device
Refrigerant control device
Connectable outdoor unit
Diameter of
Liquid
(R410A)
refrigerant
(R22 )
pipe
Gas
(R410A)
(O.D.)
(R22 )
Diameter of drain pipe
Drawing
External
Wiring
Refrigerant cycle
Standard
Document
attachment
Accessory
Optional
External heater adaptor
parts
Remark
Installation
Note :
*1 Nominal cooling conditions
Indoor :
80degF D.B. / 67degF W.B.
(26.7degC D.B. / 19.4degC W.B.)
Outdoor :
95degF D.B.
(35degC D.B.)
Pipe length :
25 ft. (7.6 m)
Level difference :
0 ft. (0 m)
*The external static pressure is set to 15 Pa at factory shipment.
*Due to continuing improvement, above specification may be subject to change without notice.
HWE1833B
TPEFYP018MS140C
BTU / h
18,000
kW
5.3
kW
0.09/0.09
A
0.74/0.70
BTU / h
20,000
kW
5.9
kW
0.07/0.07
A
0.64/0.60
in.
7-7/8 x 39 x 27-9/16
mm
200 x 990 x 700
lbs (kg)
53(24)
Sirocco fan x 3
0.02-0.06-0.14-0.20
in.WG
(208V)
Pa
5-15-35-50
0.02-0.06-0.14-0.20
in.WG
(230V)
Pa
5-15-35-50
kW
0.096
cfm
353-441-529
m3 / min
10-12.5-15
L / s
167-208-250
dB <A>
30-34-37 (208V)
dB <A>
30-34-37 (230V)
dB <A>
-
R410A CITY MULTI
1/4 (6.35) Brazed
in. (mm)
3/8 (9.52) Brazed
1/2 (12.7) Brazed
in. (mm)
5/8 (15.88) Brazed
in. (mm)
O.D. 1-1/4(32)
PAC-YU25HT
Details on foundation work, duct work, insulation work, electrical wiring, power source switch, and other
items shall be referred to the Installation Manual.
*2 Nominal heating conditions
70degF D.B.
(21.1degC D.B.)
47degF D.B. / 43degF W.B.
(8.3degC D.B. / 6.1degC W.B.)
25 ft. (7.6 m)
0 ft. (0 m)
TPEFYP024MS140C
1-phase 208/230V 60Hz
24,000
7.0
0.12/0.12
0.98/0.93
27,000
7.9
0.10/0.10
0.88/0.83
Galvanized
7-7/8 x 46-7/8 x 27-9/16
200 x 1190 x 700
60(27)
Cross fin(Aluminium fin and copper tube)
Sirocco fan x 4
0.02-0.06-0.14-0.20
(208V)
5-15-35-50
0.02-0.06-0.14-
0.20(230V)
5-15-35-50
DC brushless motor
0.096
Direct-driven
423-565-706
12-16-20
200-267-333
30-35-40 (208V)
30-35-40 (230V)
-
Polystyrene foam,Polyethylene foam,Urethane foam
PP Honeycomb fabric (washable)
Fuse
LEV
R410A CITY MULTI
3/8 (9.52) Brazed
3/8 (9.52) Brazed
5/8 (15.88) Brazed
5/8 (15.88) Brazed
O.D. 1-1/4(32)
WKB94L522
WKB94L523
-
Installation Manual, Instruction Book
Drain hose (flexible joint)
PAC-YU25HT
- 6 -
Unit convertor
kcal/h = kW x 860
BTU/h = kW x 3,412
cfm = m3/min x 35.31
lbs = kg / 0.4536
*Above specification data is
subject to rounding variation.