COMPONENTS REQUIRED TOOLS Supplied Not supplied Spanner Box cutter Phillips screwdriver Level PARTS Supplied Supplied (not required*) 1x Cold water hose 1x Communication cable 1x Hot water hose 1x Blanking cap 7x Plugs *Not required for single product installation.
Page 3
ACCESSING YOUR PRODUCT SPECIFICATIONS For full product, cabinetry and service specifications, refer to the Planning Guide. To access the Planning Guide, scan the QR code or visit fisherpaykel.com/specify. Search by appliance type, product name or model code.
PRIOR TO INSTALLATION 1. Ensure cabinetry and servicing specifications have been met and clearances have been considered. Refer to the Planning Guide for details. fisherpaykel.com/specify 2. Ensure floor is level and clear and a finished return has been created. 3. Ensure power will remain accessible following install to allow access for any future product maintenance.
Page 5
UNPACK 1. Cut the straps and the line printed on the top of the carton. Lift to remove. Discard braces and corner posts. Remove any packaging and accessories from the drum and base packer. 2. Dispose of packaging responsibly. 3. Protect flooring before positioning washer as close to the installation location as possible, ensuring enough...
REMOVE TRANSIT BOLTS 1. Using the supplied spanner, remove all four transit bolts from the back of the washer. 2. Pull the rubber grommets and spacers outwards to remove. 3. Using a Phillips screwdriver, remove the two side brackets.
Page 7
REMOVE TRANSIT BOLTS 4. Remove and discard the braces. 5. Pull the two transit rods outwards to remove. Set aside for future use. 6. Cover the transit bolt holes using the supplied plugs.
Page 8
LEVEL 1. Adjust the feet using the supplied spanner until the washer is level front to back and corner to corner. 2. Once level, move the washer into its final position allowing for required clearances. Recheck washer is level before removing from the alcove.
Page 9
CONNECT CABLES AND HOSES 1. Refer to the Planning Guide for full service information. Supply: 220 - 240V, 50Hz Service: 10A Outlet: 3-prong grounding-type Supply: Hoses provided Pressure: 50KPa (7psi) - 1MPa (150psi). Min 6 litres/min. fisherpaykel.com/specify 2. Connect the angled end of cold hose to the cold water inlet on the washer.
Page 10
CONNECT CABLES AND HOSES 4. Partially push products into the alcove. Take care not to crush the cables and hoses. 5. Route the power cables and hoses through service holes. Ensure power will remain accessible following install to allow access for any future product maintenance.
Page 11
CONNECT CABLES AND HOSES 7A. Standpipe Installations: Route the drain hose through the guide and place into the 20mm standpipe. Ensure a maximum of 20mm of the hose rests in the standpipe. 7B. Spigot Installations: Drill out blanking insert from the spigot.
Page 12
CONNECT CABLES AND HOSES 9. Connect the power cable and check washer is powered on and connected.
Page 13
INSTALL WASHER 1. Push washer into the alcove. Take care not to damage hoses or power cord. 2. Check alignment and ensure required clearances are maintained. Adjust as required.