EARTHSTONE OVENS PRE-ASSEMBLED GAS OVEN INSTALLATION INSTRUCTIONS – ETL LISTED
MINIMUM CLEARANCES TO COMBUSTIBLE AND NON COMBUSTIBLE CONSTRUCTION.
COMBUSTIBLES:
NON COMBUSTIBLES
ADEQUATE CLEARANCE MUST BE PROVIDED FOR AIR OPENINGS INTO THE COMBUSTION
CHAMBER, FOR SERVICING AND PROPER OPERATION (PAG AND PAGW MODELS ONLY). A
MINIMUM OPENING OF 24" X 24" MUST BE LOCATED ON THE BOTTOM HALF OF THE OVEN. THIS
WILL ALLOW FOR PROPER COMBUSTION AIR INTO THE BURNER HOUSING.
PROPER COMBUSTION AIR WILL CAUSE IMPROPER OPERATION AND MAY CAUSE DAMAGE TO
THE BURNER SYSTEM. INSTALLING A SEALED ENCLOSURE AROUND THE OVEN SHELL MAY ALSO
CAUSE IMPROPER OPERATION BY STARVING THE BURNER SYSTEM OF COMBUSTION AIR. THE
USE OF RETURN AIR SYSTEMS OR OTHER VENTING SYSTEMS LOCATED WITHIN SEALED
ENCLOSURES WHICH SURROUND THE OVEN MAY CAUSE NEGATIVE PRESSURE AND IN TURN
AFFECT THE OPERATION OF THE OVEN. ***SEE PAGES 14 AND 15 FOR MORE INFORMATION
FOR MORE INFORMATION PLEASE CALL: 800-840-4915 OR 818-553-1134
KEEP APPLIANCE FREE AND CLEAR FROM COMBUSTIBLES.
DO NOT OBSTRUCT THE FLOW OF COMBUSTION AND VENTILATION AIR TO THE APPLIANCE.
ELECTRICAL DIAGRAM IS LOCATED ON THE CONTROL BOX.
INSTALLATION MUST CONFORM WITH LOCAL CODES, OR IN THE ABSENCE OF LOCAL CODES, WITH THE
NATIONAL FUEL GAS CODE ANSI Z223.1, THE NATURAL GAS INSTALLATION CODE CAN/CGA-B149.1 OR THE
PROPANE INSTALLATION CODE CAN/CGA-149.2, AS APPLICABLE, INCLUDING:
1
THE APPLIANCE AND ITS INDIVIDUAL SHUT OFF VALVE MUST BE DISCONNECTED FROM THE GAS
SUPPLY PIPING SYSTEM DURING ANY PRESSURE TESTING OF THAT SYSTEM AT TEST PRESSURES IN EXCESS OF ½
PSI (3.45 Kpa).
2
THE APPLIANCE MUST BE ISOLATED FROM THE GAS SUPPLY PIPING SYSTEM BY CLOSING ITS
INDIVIDUAL MANUAL SHUTOFF VALVE DURING ANY PRESSURE TESTING OF THE GAS SUPPLY PIPING SYSTEM
AT THE TEST PRESSURES EQUAL TO OR LESS THAN ½ PSI (3.45 Kpa ).
THIS APPLIANCE, WHEN INSTALLED, MUST BE ELECTRICALLY GROUNDED IN ACCORDANCE WITH LOCAL
CODES, OR IN THE ABSENCE OF LOCAL CODES, WITH THE NATIONAL ELECTRICAL CODE, ANSI/NFPA 70 OR THE
CANADIAN ELECTRICAL CODE, CSA C22.1, AS APPLICABLE.
ELECTRICAL AND GAS REQUIREMENTS:
-1 120VAC – 2.5 AMP OUTLET
-¾ INCH GAS OUTLET
-GAS INLET PRESSURE TO OVEN: 7" W.C. FOR NATURAL, 12" W.C. FOR LP GAS
-GAS REGULATING VALVE (I.E. MAXITROL RV 53, 3-6) AND SHUTOFF VALVE BY OTHERS
MANIFOLD GAS PRESSURE – FACTORY SETTINGS
160-PAG(W) 4.5" W.C. - .170,000 BTU
120-PAG(W) 3.5" W.C. - 130,000 BTU
90-PAG(W)
4.0 " W.C. - 85,000 BTU
For LP Gas see page 17
IMPORTANT INFORMATION
SIDES 1"
BACK 1"
SIDES 0"
BACK 0"
130-PAG(W) 5.0" W.C. - 140,000 BTU
110-PAG(W) 5.0" W.C. - 110,000 BTU