EARTHSTONE OVENS PRE-ASSEMBLED GAS OVEN INSTALLATION INSTRUCTIONS – ETL LISTED
CLEARANCE INFORMATION FOR FACADES
36"
1 inch minimum
clearance to
combustibles
If this area is to be covered with a facade it
must be of a non-combustable material.
Temperature gauge and On/off switch can be
extended to attach over facade.
30"
1 inch minimum clearance to combustibles
Facade
Flue Collar
Models 90 and 110 - 6 inch diameter
Models 130 and 160 - 8 inch diameter
Air gap must be sealed with a non
combustible strip. e.g. Aluminum or s/s
Any adjacent combustible floor which projects
in front of the oven opening must be a
minimum of 30 inches away from each side of
the door opening and 36 inches from the front
of the door opening.
On/off switch for gas burner
Temperature gauge
Do not block the notch exhaust port or the
underside of the primary hood.
Granite mantle
Burner control box, for PAGW models only. Adequate
clearance must be provided for air openings into the
combustion chamber for
operation
. Minimum 24" x 24" located on the bottom half
of the oven. Installing a sealed enclosure around the oven
shell may also cause improper operation by starving the
burner system of combustion air. Also the use of return air
or other venting systems located within sealed enclosures
which surround the oven may cause negative pressure.