Mitsubishi Electric FR-A520-0.4K Instruction Manual page 144

Hide thumbs Also See for FR-A520-0.4K:
Table of Contents

Advertisement

7) Sum check code
The sum check code is 2-digit ASCII (hexadecimal) representing the lower 1 byte (8 bits) of the sum
(binary) derived from the checked ASCII data.
(Example1)
Computer→Inverter
ASCII code→
When Pr. 123 "waiting time setting" ≠ 9999, create the communication request data with no "waiting time" in the data format.
The number of characters is decreased by 1.)
(Example2)
Inverter→Computer
ASCII code→
8) Error code
If any error is found in the data received by the inverter, its definition is sent back to the computer together
with the NAK code. (Refer to page 139.)
Station
Instruction
ENQ
number
code
0
1
E
1
1
H05
H30 H31
H45 H31
H31
H30 H37 H41 H44 H46 H34
H
H
H
H
H
H
H
30 + 31 + 45 + 31 + 31 + 30 + 37 + 41 + 44
H
=1F4
Sum
Station
STX
Read data
number
0
1
1
7
7
H02
H30 H31
H31 H37
H37
H30 H03 H33 H30
H
H
H
H
H
H
30 + 31 + 31 + 37 + 37 + 30
H
=130
Sum
135
Get other manuals https://www.bkmanuals.com
PARAMETERS
Sum check
Data
code
←Binary code
0
7
A
D
F
4
H
H
Sum check
ETX
code
←Binary code
0
3
0
4

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents