3 Third party components
To install the air purge valves on the highest
points of the water circuit
Prerequisite: Turn OFF the unit via the user interface.
Prerequisite: Turn OFF the respective circuit breaker.
1 Install air purge valves on all highest points of the installation
outside the unit.
2 Purge the air out of the water circuit, see
procedures" on
page 96.
Is the problem solved?
Yes
No
To remove the external heat source from the water
circuit
1 Remove the external heat source from the installation outside
the unit.
Is the problem solved?
Yes
No
To install a by-pass in the water circuit
Prerequisite: Turn OFF the unit via the user interface.
Prerequisite: Turn OFF the respective circuit breaker.
1 Install a by‑pass in the water circuit outside the installation as
shown below.
a
By‑pass
b
Underfloor heating circuit
c
Radiators circuit
Is the problem solved?
Yes
No
To replace the leaking domestic hot water tap from
in water circuit
1 Replace the leaking domestic hot water tap in the water circuit
with a correct one.
Is the problem solved?
Yes
No
To repair the leak in the water circuit
1 Repair the leak in the water circuit.
Service manual
98
"3.3.2  Repair
Action
No further actions required.
Return to
"To check the air purge
valves" on page 95
and continue
with the next procedure.
Action
No further actions required.
Return to the troubleshooting of
the specific error and continue
with the next procedure.
a
b
c
Action
No further actions required.
Return to the troubleshooting of
the specific error and continue
with the next procedure.
Action
No further actions required.
Return to the troubleshooting of
the specific error and continue
with the next procedure.
Is the problem solved?
Yes
No
To adjust the main water supply of the installation
1 Adjust the main water supply of the installation to be within the
expected range (>1 bar).
Is the problem solved?
Yes
No
3.4

Manuafacturer components

3.4.1

Checking procedures

To check the correct operation / setting of the third
party component
1 See the specific dealer manual to check for the correct
installation, operation or setting of your component.
Does the component function
correctly?
Yes
No
3.4.2

Repair procedures

To adjust the third party component
1 See the specific dealer manual to adjust your component.
Is the problem solved?
Yes
No
3.5

External factors

3.5.1
Checking procedures
To check the outdoor temperature
1 The outdoor unit is designed to operate within a temperature
range of –25°C and 35°C. If the outdoor temperature is outside
this range, the outdoor unit may stop operating.
Is the outdoor temperature
within the operating range?
Yes
No
EBLQ+EDLQ011~016CAV3+W1 + EBLQ+EDLQ011~016CA3V3+W1
+ EK(2)CB07CAV3 + EKMBUHCA3V3+9W1
Action
No further actions required.
Return to the troubleshooting of
the specific error and continue
with the next procedure.
Action
No further actions required.
Return to the troubleshooting of
the specific error and continue
with the next procedure.
Action
Return to the troubleshooting of
the specific error and continue
with the next procedure.
Adjust the specific component,
see
"3.4.2 Repair procedures" on
page 98.
Action
No further actions required.
Return to the troubleshooting of
the specific error and continue
with the next procedure.
Action
Return to the troubleshooting of
the specific error and continue
with the next procedure.
Wait for the outdoor temperature
to return within the operating
range.