6. ELECTRICAL DATA

6-1. Electrical Characteristics

Indoor Unit
SAP – K181AA
Outdoor Unit
SAP – C181AA
Performance at
Rating Conditions
Full Load Conditions Running Amps.
Rating Conditions
Full Load Conditions : Indoor Air Temperature 32°C D.B. / 23°C W.B.
Indoor Unit
SAP – K241AA
Outdoor Unit
SAP – C241AA
Performance at
Rating Conditions
Full Load Conditions Running Amps.
Rating Conditions
Full Load Conditions : Indoor Air Temperature 32°C D.B. / 23°C W.B.
Indoor Unit
Running Amps.
A
Power Input
kW
A
Power Input
kW
: Indoor Air Temperature 27°C D.B. / 19°C W.B.
Outdoor Air Temperature 35°C D.B.
Outdoor Air Temperature 43°C D.B.
Indoor Unit
Running Amps.
A
Power Input
kW
A
Power Input
kW
: Indoor Air Temperature 27°C D.B. / 19°C W.B.
Outdoor Air Temperature 35°C D.B.
Outdoor Air Temperature 43°C D.B.
Fan Motor
Fan Motor
240V Single phase 50Hz
0.38
0.50
0.073
0.119
0.38
0.50
0.073
0.119
Fan Motor
Fan Motor
240V Single phase 50Hz
0.40
0.50
0.080
0.118
0.40
0.50
0.080
0.118
17
Outdoor Unit
Compressor
8.72
1.988
10.52
2.478
Outdoor Unit
Compressor
12.30
2.632
14.80
3.262
Complete Unit
9.6
2.18
11.4
2.67
Complete Unit
13.2
2.83
15.7
3.46