MAGNUM PRO
CURVE HDE 250, 350, 450 & 550
Connection to Miller Feeders
Gun and cable assemblies which were assembled with a K466-3
connection kit will connect easily to a variety of popular Miller wire
feeders.
a. Check that the gun liner, connector cap liner, driverolls and
guide tubes are appropriate for the electrode size being used.
b. Fully push the brass connector end of the gun and cable into
the connector receptacle on the outgoing side of the feeder
wire drive. Tighten the hand screw to clamp down on the
connector.
c. Insert the control cable plug from the feeder trigger circuit
into the mating socket on the gun cable connector hand
Connection To Power MIG
Gun cable assemblies which were assembled with a K466-6,
Connection Kit will connect easily to a feeder.
a. Check that the adapter and feeder outgoing guide, as well as
the drive roll, are appropriate for the electrode size being
used.
b. Fully push the brass connector end of the gun cable into the
outgoing side of the feeder wire drive. Secure the cable using
the hand screw on the wire feeder.
c. Insert the control cable plug from the feeder trigger circuit
into the mating socket on the gun cable connector handle.
Connection To Lincoln 10 Series Feeders
Gun cable assemblies which were assembled with a K466-10
Connection Kit will connect easily to a 10 Series feeder.
a. Check that the K1500-2 gun adapter is in place on the wire
feeder. Check that the feeder guide tubes, as well as the
drive roll(s), are appropriate for the electrode size being used.
b. Fully push the brass connector end of the gun cable into the
gun adapter on the outgoing side of the feeder wire drive and
secure the cable using the hand screw.
c. Insert the control cable plug from the feeder trigger circuit
into the mating socket on the gun cable connector handle.
®
®