Important! Important! It is essential that you read the instructions in this manual before assembling, It is essential that you read the instructions in this manual before assembling, operating, and maintaining the product. operating, and maintaining the product. Subject to technical modification. Subject to technical modification.
Safety, performance, and dependability have Check with your local authority for advice. been given top priority in the design of your ■ Wear hearing protection at all times while cordless blower/vacuum. operating the product. The product is noisy, and permanent hearing injury may result if INTENDED USE precautions to limit your exposure, reduce noise, and wear hearing protection are not...
OPERATION WARNING ■ Before starting the product, make sure the Before using the product in vacuum mode, feeding chamber is empty. you must assemble the upper and lower ■ Keep your face and body away from the vacuum tubes together. This is a one–time feed intake opening.
Make sure that all moving parts have come ■ Do not point the blower nozzle in the to a complete stop: direction of people or pets. – before leaving the product unattended ■ Never place objects inside the blower tubes. –...
bottles, cans, or other foreign objects are MAINTENANCE not included. ■ Do not allow processed material to build WARNING up in the discharge zone. This may prevent only original manufacturer’s proper discharge and can result in kickback replacement parts, accessories of material through the intake opening.
Manual x 1 – Wear eye protection at all times. ■ Locking screw x 1 NOTE: For RBV3600, the battery and charger RISK REDUCTION are sold separately. It has been reported that vibrations from NOTE: When replacing the vacuum bag,...
CAUTION Without safety alert symbol Wear ear protection. Indicates a situation that may result in property damage. Wear eye protection. Do not expose the product to rain or damp condition. Regulatory Compliance Mark (RCM). This product meets applicable regulatory requirements. Waste electrical products should not be disposed of with household waste.
Page 9
WHAT’S IN THE BOX RBV3650D RBV365 RBV3640 * Kit includes battery and charger.
Page 10
WHAT’S IN THE BOX RBV3600 * Battery and charger are sold separately.
Page 11
Know your product KNOW YOUR PRODUCT 1. Front handle 11. Lower blower tube 2. Quick release handle 12. High speed nozzle 3. Shoulder/strap pad 13. Guide wheels 4. Cruise control lever 14. Lower vacuum tube 5. Rear handle 15. Upper vacuum tube 6.
Page 12
GETTING STARTED Wear full eye and ear protection, substantial footwear, and Push the high speed nozzle into the lower blower tube until long trousers at all times while operating the product. Do it locks into place. Slide the guide wheels onto the lower not operate the product when barefoot or wearing open blower tube.
Page 13
GETTING STARTED GETTING STARTED GETTING STARTED Connect the high speed nozzle/lower blower tube to the upper blower tube, then push until you hear an audible click, and Push the lower vacuum tube into the upper vacuum tube Turn the locking screw counterclockwise to unlock the fan Push the lower/upper vacuum tube into the fan housing WARNING: Never operate the vacuum with only the the tube locks into place.
OPERATION BLOWER MODE 1. At the rear side of the housing, insert the battery pack until you hear an audible click and the battery locks into place. Set the mode selection lever to the bottom position to set the product to blower mode.
OPERATION BLOWER SETUP 1. Remove the battery pack. Press the latch to unlock and then pull the battery pack out of the housing. 2. Attach the high speed nozzle and guide wheels to the lower blower tube. Push the high speed nozzle into the lower blower tube until it locks into place.
Page 18
OPERATION 5. Hook the harness to the front handle. 6. At the rear side of the housing, insert the battery pack until you hear an audible click and the battery locks into place. 7. Set the mode selection lever to the bottom position to set the product to blower mode.
OPERATION VACUUM SETUP 1. Remove the battery pack. Press the latch to unlock and then pull the battery pack out of the housing. 2. Push the lower vacuum tube into the upper vacuum tube until you hear and audible click and the tube locks into place.
Page 20
OPERATION 5. Guide the vacuum bag opening over the bag adaptor and then snap the rear side of the bag to secure it in place. Hook the vacuum bag to the lower blower tube. 6. Hook the harness to the front handle. 7.
Page 21
OPERATION EMPTYING THE VAC BAG 1. Remove the battery pack. Press the latch to unlock and then pull the battery pack out of the housing. 2. Remove the vacuum bag. Unhook the vacuum bag from the lower blower tube. At the rear side of the vacuum bag opening, unlatch the locking tab from the bag adaptor and then remove the vacuum bag.
Page 22
MAINTENANCE MAINTENANCE 1. Remove the battery pack. Press the latch to unlock and then pull the battery pack out of the housing. 2. Clean the product using a brush. WARNING: Avoid using solvents when cleaning plastic parts. Most plastics are susceptible to damage from various types of commercial solvents and may be damaged by their use.
Page 23
STORAGE STORAGE 1. Remove the battery pack and vacuum bag. Press the latch to unlock and then pull the battery pack out of the housing. Unhook the vacuum bag from the lower blower tube. At the rear side of the vacuum bag opening, unlatch the locking tab from the bag adaptor and then remove the vacuum bag.
PRODUCT SPECIFICATIONS The declared vibration value has been Cordless Blower/Vacuum measured with a standard test method and Model RBV3600/RBV3640/RBV365/ may be used to compare one tool with another. RBV3650D The declared vibration value may be used in a Rated voltage 36 V preliminary assessment of exposure.
Page 28
Techtronic Industries Australia Pty Ltd 31 Gilby Road, Mount Waverley, VIC 3149, Melbourne, Australia Techtronic Industries N.Z. Limited Unit C, 70 Business Parade South, RYOBI is a trademark of Ryobi Limited, Highbrook, Auckland 2013, New Zealand and is used under license. 961087090-01...