Cooling Fans; Removing The Cooling Fan - Dell PowerEdge T350 57C92 Installation And Service Manual

Table of Contents

Advertisement

3.
Remove the front
bezel.
4.
Remove all the
drives.
CAUTION:
To prevent damage to the drives and backplane, remove the drives from the system before
removing the backplane.
5.
Remove the air
shroud.
6. Disconnect the cables from the drive backplane.
Steps
1. Align the slots on the drive backplane with the guides on the system.
2. Slide the drive backplane into the guides and lower the backplane until the blue release tabs clicks into place.
Figure 39. Installing the drive backplane
Next steps
1. Connect the cables into the drive backplane.
2.
Install the air
shroud.
3.
Install the
drives.
4.
Install the front
bezel.
5. Follow the procedure listed in

Cooling fans

Removing the cooling fan

Prerequisites
CAUTION:
Never operate your system with the fan removed. The system can overheat and result in shutdown of
the system and loss of data.
1. Follow the safety guidelines listed in
54
Installing and removing system components
After working inside your
Safety
instructions.
system.