Measuring
Item
instrument
H. POSITION
Signal
adjustment
generator
Remote
control unit
C
V.LINEARITY
Signal
adjustment
generator
Remote
control unit
H. PARALLEL
Signal
adjustment
generator
Remote
control unit
Test point
Adjustment part
[4. DEF]
4. H-CENT
D
[4. DEF]
12. V-S. CR
13. V-LIN
TOP
CENTRE
BOTTOM
[4.DEF]
10. ANGLE
Parallel
Description
- PAL H. POSITION -
(1) Receive a PAL circle pattern signal.
(2) Select 4. H-CENT.
(3) Set the initial setting value of 4. H-CENT.
(4) Adjust 4. H-CENT to make "C = D".
- NTSC H. POSITION -
(1) Input a NTSC circle pattern signal.
(2) Make similar adjustment of NTSC H. POSITION in
the same way as for "PAL H. POSITION".
- PAL V. LINEARITY -
(1) Receive a PAL crosshatch signal.
(2) Select 12. V-S.CR.
(3) Set the initial setting value of 12. V-S. CR.
(4) Select 13. V-LIN.
(5) Set the initial setting value of 13. V-LIN.
(6) Adjust 12. V-S. CR and 13. V-LIN so that the spaces
of each line on TOP, CENTRE and BOTTOM
become uniform.
- NTSC V. LINEARITY -
(1) Input a NTSC crosshatch signal.
(2) Make similar adjustment of NTSC V-S. CR in the
same way as for "PAL V-S. CR".
- PAL H. PARALLEL -
(1) Receive a PAL crosshatch signal.
(2) Select 10. ANGLE.
(3) Set the initial setting value of 10. ANGLE.
(4) Adjust 10. ANGLE to optimize the trapezium
distortion at the centre of the screen.
- NTSC H. PARALLEL -
(1) Input a NTSC crosshatch signal.
(2) Make similar adjustment of NTSC H. PARALLEL in
the same way as for "PAL H. PARALLEL".
(No.YA124)1-25