Discharge Page; Lipo, Liion, Life, Nicd, Nimh, Pb Battery Discharge Modes - GRAUPNER S2003 Operating Instruction

2 channels dc charger
Table of Contents

Advertisement

This page (left) shows the charging process with the parameters
and graph. Both the voltage and current will increase to the preset
parameters. The preset current may be limited by the charge/dis-
charge capacity and the input voltage setup. The maximum charging
process can operate with 500W by CH 1 and 30W by CH 2.
Tapping the graph will access the data view page.
The operating data can be displayed.
Please refer to pages 27-29 for further information.
Tapping the part in the red circle (image to the left), the set cur-
rent window will appear. The operating charge current can then
be set. Tapping the X button will cause the set current window to
disappear.
This setup is applied to the charger during the charging process
and the parameters are not stored in the memory.
Pressing the STOP button will cause a pop-up window to ap-
pear, asking whether to stop operating. Tapping the STOP or
ESC buttons will cause the charger to either stop or continue
with the charging process, respectively.
19

◎ DISCHARGE PAGE

Tapping the DISCHARGE icon on the main page will access the discharge mode. The pro-
gramming setup and the page transition are the same as described for the CHARGE mode.
USER NAME
This page shows discharge setup for selecting
LiPo, Lilon, LiFe, NiCd, NiMH, Pb batteries
To program the battery parameters, tap each data box,
activating to a blue color.
To edit the battery parameters, tap the INC/DEC buttons

LiPo, LiIon, LiFe, NiCd, NiMH, Pb battery discharge modes

- Voltage
: Final discharge voltage for each cell can be programmed
- Current
: Discharge current. - The CH1 could be configured from 0.1A to 10A (to be operated within
60W) and CH2 could be configured from 0.1A to 1.0A (to be operated within 5W).
- Cut-Temp
: Cut-off temperature. - With an optional temperature sensor, a safety cut-off temperature
can be set, allowing the charging or discharging process to terminate automatically for
battery temperatures exceeding the preset temperature.
- Max Capacity
: The maximum capacity setting is used to terminate a discharge at battery capaci-
ties exceeding a preset percentage value. Damaged, poorly balanced or improperly
programmed battery parameters can result in an overdischarge.
On the main page, tap the DISCHARGE
icon to start the discharge process.
20