Installation Step 6
Install the Multi-Function
Door Control Panel
• Strip 1/4" of insulation from one end of the bell
wire; connect the wire to the two screw terminals
on the back of the door control by color: white to 2
and white/red to 1.
• Locate the door control within sight of the door
at a minimum height of 5 feet where small
children cannot reach, and away from all
moving parts of the door and door hardware.
Fasten the Multi-Function Door Control securely
with 6ABx1" screws. If installing into drywall, drill
5/32" holes and use the anchors provided.
• Run the bell wire up the wall and across the ceiling
to the opener. Use insulated staples to secure the
wire in several places. Be careful not to pierce the
wire with a staple, creating a short.
• Receiver terminal screws and the antenna are
located on the right panel of the opener. Position
the antenna wire as shown.
• Then connect the bell wire to the opener terminal
screws: white to 2 and white/red to 1.
• Remember to affix the User Safety Instruction
label to the wall near the door control, and the
The Chamberlain Group, Inc.
Maintenance Instruction label in a prominent
location on the inside of the garage door.
Liftmaster Belt Drive CDO
If the label adhesive will not adhere to your garage
Install Wall Control
wall surface (or becomes loose with time) use tacks
3/5/92 - 3/13/92
to secure the label alongside the door control.
Page 28 explains how to operate the opener using
the lighted push button and the Lock & Light
features available on the Multi-Function Door
Control Panel.
Hardware Shown Actual Size
6AB x 1" Screw
Multi-Function Door Control
Lock Button
L O C K
Multi-Function
Door Control Panel
Dry Wall Anchors
L IG H T
Light Button
Door Control
Button
Children operating or playing with a garage
door opener can injure themselves or others.
The garage door could close and cause
serious injury or death. Install the door control
(or any additional push buttons) out of the
reach of children and away from all moving
parts of the door and door hardware, but
where the garage door is visible. Do not allow
children to operate the push button(s) or the
remote control transmitter(s).
A moving garage door could injure someone
under it. Activate the opener only when the
door is properly adjusted, you can see it clearly,
and there are no obstructions to door travel.
Do NOT connect the power and operate the
opener at this time. The trolley will travel to the
full open position but will not return to the
close position until the sensor beam is
connected and properly aligned.
See Safety Reversing Sensor Instructions
beginning on page 17.
Outside Keylock Accessory Connections
To opener terminal screws: white to 2; white/red to 1
Insulated
Staples
Right Panel
of Opener
14
WARNING
Multi-Function
Door Control Panel
Terminal Screws
RE D
WH ITE
1
2
Opener
Terminal Screws
1
TO PROGRAM RECEIVER CODE
2
3
FOR EACH REMOTE CONTROL
1. Press and HOLD remote control
transmitter push button.
2. Press receiver code button. The opener
light will flash once.
3. Release transmnitter button. Opener
has learned code.
TO ERASE ALL RECEIVER CODES
9
9
1
1
1. Press and HOLD receiver code button.
Green indicator light alongside will turn
7
3
7
3
ON.
5
5
2. When light turns OFF (about 6
KG
seconds) ALL codes are erased from
KG
opener memory.
This device complies
WARNING: To reduce the risk of severe injury
with FCC Rules Part
or death by entrapment, when adjusting either
the force or limits of travel controls ensure that
15. Operation of this
the door reverses on a 1 inch object (or a 2 x 4
device is subject to the
board laid flat). See instructions for proper
following conditions:
adjustment procedure.
1. This device may
AVERTISSEMENT: Pour réduire les risques de
not cause harmful
blessures mortelles par happement, après tout
interference. 2. This
réglage de la force de déclenchement ou des
device must accept
seuils de fin de course s'assurer que le sens de
any interference
la course s'inverse lorsque la porte entre en
contact avec un object de 13 mm (1 po) de
that may be received,
including interference
hauteur (ou un madrier de 2 x 4 de section, à
plat) posé sur le sol. Effectuer les reglages
that may cause
selon les procédures décrites dans la notice.
undesired operation.
PART NO:
Nº DE PIÈCE:
D.O.C. CERT. NO.
DATE:
PAT. #RE29,525; 4,750,201; 4,806,930 Other Patents Pending.
M.D.C. CERT. NO.
132C2105-1
Antenna

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for: