Download Print this page

Speed Queen AFB50R User Manual page 28

Hide thumbs Also See for AFB50R:

Advertisement

Vacations and Extended
Non-Use
• To avoid possible property damage due to
flooding, turn off the water supply to the
washer whenever there will be an extended
period of non-use.
• Leave the loading door open during extended
periods of non-use to allow the wash drum to
dry out and avoid a musty smell.
Reinstallation of Shipping
Materials
To prevent damage while moving the unit, the
shipping materials MUST be reinstalled.
• Disconnect washer from electrical supply.
• While supporting the front access panel,
remove two screws from the bottom edge of
the panel.
• Gently lower the panel to remove it from the
washer.
• Place the shock sleeves on all four shock
absorbers. Refer to the illustration below.
• Insert hooked end of shipping brace into the
open slot of the motor mount.
• Attach the brace with the five bolts and
washers. Refer to the illustration below.
• Reinstall front access panel.
Bolts and Lockwashers
Refer to the INSTALLATION INSTRUCTIONS for
proper procedures whenever the washer is moved.
Cleaning Foreign Object Trap
The washer's pump has a trap that may collect
foreign objects. The trap may need to be cleaned if
water is draining slower than usual. To clean:
• Disconnect washer from electrical supply.
• While supporting the front access panel,
remove two screws from the bottom edge of
the panel.
• Gently lower the panel to remove it from the
washer.
NOTE: The pump may have some water in it. Use
a rag or a container to catch water. If the wash
drum is full of water, use a wet/dry shop vacuum
to catch the water.
• With rag or vacuum ready, unscrew the cap
on the left side of the pump and remove trap.
• Clean the debris from the trap.
• Reinstall the trap and access panel.
• Reconnect washer to electrical supply.
-28-
803236
Shock
Sleeves
Motor
Mount
Hooked End of
Shipping Brace
FLW2182N
FLW2182N

Advertisement

loading