York YBS006-070 Installation Manual page 7

Lx compact commercial geothermal/ water source heat pumps single capacity
Table of Contents

Advertisement

Vertical Dimensional Data cont.
Overall Cabinet
Vertical
Models
A
Width
in.
19.2
006-012
cm.
48.8
in.
22.5
015-018
cm.
57.2
in.
22.5
024-030
cm.
57.2
in.
22.5
036
cm.
57.2
in.
21.5
041
cm.
54.6
in.
22.5
042-048
cm.
57.2
in.
25.5
060
cm.
64.8
in.
25.5
070
cm.
64.8
Vertical
N
Models
Supply Width
in.
10.0
006-012
cm.
25.4
in.
14.0
015-018
cm.
35.6
in.
14.0
024-030
cm.
35.6
in.
14.0
036
cm.
35.6
in.
14.0
041
cm.
35.6
in.
18.0
042-048
cm.
45.7
in.
18.0
060
cm.
45.7
in.
18.0
070
cm.
45.7
Condensate is 3/4" PVC female glue socket and is switchable from side to front.
*Discharge fl ange is fi eld installed and extends 1" (25.4 mm) from top of cabinet.
**Vertical units shipped with standard 2" (fi eld adjustable to 1") open application fi lter rack extending 2.2" from unit and is not suitable for duct connection.
For ductable return connection applications, order the deluxe 2" (fi eld adjustable to 1") duct collar/fi lter rack which extends 3.25
Vertical Disconnect
When using disconnect, do not use dimension L from the standard
vertical dimensional data. Use dimension LL from the vertical
disconnect dimensional data.
Vertical Models
015-018
024-030
036
042-048
060
070
Dimensions in inches [cm]
* Models 006-012 - Externally Mounted Disconnect
**UBV-041 - Disconnect not available
1
B
C
D
Depth
Height*
In
Out
19.2
24.2
2.6
5.6
48.8
61.5
6.6
14.2
22.2
30.2
2.6
7.6
56.4
76.7
6.6
19.3
22.2
36.2
2.6
7.6
56.4
91.9
6.6
19.3
26.2
40.2
2.6
7.6
66.5
102.1
6.6
19.3
21.5
40.2
2.6
7.6
54.6
102.1
6.6
19.3
26.2
44.2
2.6
7.6
66.5
112.3
6.6
19.3
31.2
44.2
2.6
7.6
79.2
112.3
6.6
19.3
31.2
48.2
2.6
7.6
79.2
122.4
6.6
19.3
Discharge Connection
duct fl ange installed (±0.10 in)
P
Q
Supply Depth
10.0
4.6
25.4
11.7
14.0
4.1
35.6
10.4
14.0
4.1
35.6
10.4
14.0
6.1
35.6
15.5
14.0
3.8
35.6
9.7
18.0
4.1
45.7
10.4
18.0
6.6
45.7
16.8
18.0
6.6
45.7
16.8
LL
15.8 [40.1]
18.8 [47.8]
15.3 [38.9]
13.8 [35.1]
14.3 [36.3]
14.3 [36.3]
LX COMPACT SERIES INSTALLATION MANUAL
Water Connections
2
5
E
H
Loop
Condensate
Water FPT
8.8
1/2"
22.4
12.7 mm
10.8
3/4"
27.4
19.1 mm
10.8
3/4"
27.4
19.1 mm
10.8
3/4"
27.4
19.1 mm
10.8
3/4"
27.4
19.1 mm
10.8
3/4"
27.4
19.1 mm
10.8
1"
27.4
25.4 mm
10.8
1"
27.4
25.4 mm
R
S
T
4.4
7.8
2.4
11.2
19.8
6.1
4.3
7.7
2.1
10.9
19.6
5.3
4.3
7.7
2.1
10.9
19.6
5.3
4.5
7.7
2.1
11.4
19.6
5.3
3.5
6.7
0.6
8.9
17.0
1.5
2.1
3.9
2.1
5.3
9.9
5.3
4.6
6.3
1.6
11.7
16.0
4.1
4.6
6.3
1.6
11.7
16.0
4.1
7
Electrical Knockouts
6
7
8
J
K
L
1/2" cond
1/2" cond
1" cond
Low
Low
Power Sup-
Voltage
Voltage
ply
7.4
3.4
5.4
18.8
8.6
13.7
9.4
5.4
7.4
23.9
13.7
18.8
9.4
5.4
7.4
23.9
13.7
18.8
10.1
6.1
8.1
25.7
15.5
20.6
9.4
5.4
7.4
23.9
13.7
18.8
10.1
6.1
8.1
25.7
15.5
20.6
10.1
6.1
8.1
25.7
15.5
20.6
10.1
6.1
8.1
25.7
15.5
20.6
**Return Connection
using deluxe fi lter rack (±0.10 in)
U
V
Return Depth
Return Height
14.3
10.1
36.3
25.7
18.1
14.0
46.0
35.6
18.1
20.0
46.0
50.8
22.1
22.1
56.1
56.1
20.2
28.0
51.3
71.1
22.1
26.1
56.1
66.3
28.1
26.0
71.4
66.0
28.1
30.0
71.4
76.2
M
Filter Rack
Width
2.2
5.6
2.2
5.6
2.2
5.6
2.2
5.6
1.2
3.0
2.2
5.6
2.2
5.6
2.2
5.6
W
2.0
5.1
2.0
5.1
2.0
5.1
2.0
5.1
0.6
1.5
2.0
5.1
2.0
5.1
2.0
5.1
10/15/15

Advertisement

Table of Contents
loading

Table of Contents