LX COMPACT SERIES INSTALLATION MANUAL
Electrical Data cont.
Variable Speed ECM Motor
Rated
Model
Voltage
115/60/1
006
208-230/60/1
115/60/1
009
208-230/60/1
115/60/1
012
208-230/60/1
208-230/60/1
015
265/60/1
208-230/60/1
018
265/60/1
208-230/60/1
265/60/1
024
208-230/60/3
460/60/3
208-230/60/1
265/60/1
030
208-230/60/3
460/60/3
208-230/60/1
265/60/1
036
208-230/60/3
460/60/3
208-230/60/1
041
208-230/60/3
460/60/3
208-230/60/1
042
208-230/60/3
460/60/3
208-230/60/1
048
208-230/60/3
460/60/3
208-230/60/1
060
208-230/60/3
460/60/3
208-230/60/1
070
208-230/60/3
460/60/3
HACR circuit breaker in USA only
Caution: When installing a unit with a Variable Speed ECM blower motor in 460/60/3 voltage, a neutral wire is
required to allow proper unit operation.
Compressor
Voltage
Min/Max
MCC
RLA
104/127
9.5
6.1
187/253
4.7
3.0
104/127
12.5
8.0
187/253
6.4
4.1
104/127
14.8
9.5
187/253
7.7
4.9
187/253
9.2
5.9
238/292
7.8
5.0
187/253
10.4
6.7
238/292
8.7
5.6
187/253
21.0
13.5
238/292
14.0
9.0
187/253
11.0
7.1
414/506
5.5
3.5
187/253
22.0
14.1
238/292
17.5
11.2
187/253
13.9
8.9
414/506
6.5
4.2
187/253
22.0
14.1
238/292
19.0
12.2
187/253
14.0
9.0
414/506
8.8
5.6
187/253
28.0
17.9
187/253
20.6
13.2
414/506
9.3
6.0
187/253
28.0
17.9
187/253
20.6
13.2
414/506
9.3
6.0
187/253
34.0
21.8
187/253
21.4
13.7
414/506
9.7
6.2
187/253
41.2
26.4
187/253
24.9
16.0
414/506
12.1
7.8
187/253
44.2
28.3
187/253
30.0
19.2
414/506
13.6
8.7
20
Blower
Total
Motor
Unit
LRA
FLA
FLA
29.0
1.8
7.9
15.0
0.9
3.9
50.0
1.8
9.8
21.0
0.9
5.0
50.0
1.8
11.25
25.0
0.9
5.8
29.0
4.0
9.9
28.0
4.1
9.1
33.5
4.0
10.7
28.0
4.1
9.7
58.3
4.0
17.5
54.0
4.1
13.1
55.4
4.0
11.1
28.0
4.1
7.6
73.0
4.0
18.1
60.0
4.1
15.3
58.0
4.0
12.9
28.0
4.1
8.3
77.0
4.0
18.1
72.0
4.1
16.3
71.0
4.0
13.0
38.0
4.1
9.7
112.0
4.0
21.9
88.0
4.0
17.2
44.0
4.1
10.1
112.0
4.0
21.9
88.0
4.0
17.2
44.0
4.1
10.1
117.0
4.0
25.8
83.1
4.0
17.7
41.0
4.1
10.3
134.0
7.0
33.4
110.0
7.0
23.0
52.0
6.9
14.7
178.0
7.0
35.3
136.0
7.0
26.2
66.1
6.9
15.6
Max
Min
Fuse/
Circ
HACR
Amp
Breaker
9.4
15
4.7
10/15
11.8
20
6.1
10/15
13.6
20
7.1
10/15
11.4
15
10.3
15
12.4
15
11.1
15
20.9
30
15.4
20
12.9
15
8.5
10/15
21.6
35
18.1
25
15.1
20
9.4
10/15
21.6
35
19.4
30
15.3
20
11.1
15
26.4
40
20.5
30
11.6
15
26.4
40
20.5
30
11.6
15
31.3
50
21.1
30
11.9
15
40.0
60
27.0
40
16.7
20
42.4
70
31.0
50
17.8
25
8/1/18