2. Reseat the failing DIMM identified by LightPath and/or event log entry
3. Restore A/C power and power on the system.
4. Check Lenovo support site for an applicable service bulletin or firmware update that applies to this
memory error.
5. If the problem persists, collect Service Data logs.
• FQXSFMA0056M: An uncorrected recoverable memory error has been detected on DIMM [arg1] at
address [arg2].[arg3]
Severity: Error
User Action:
1. Power off the system and remove A/C power.
2. Reseat the failing DIMM identified by LightPath and/or event log entry
3. Restore A/C power and power on the system.
4. Check Lenovo support site for an applicable service bulletin or firmware update that applies to this
memory error.
5. If the problem persists, collect Service Data logs.
• FQXSFMA0057G: Page Retire PFA Threshold limit exceeded on DIMM [arg1] at address [arg2].
[arg3] [arg4]
Severity: Warning
User Action:
Complete the following steps:
1. Power off the system and remove A/C power.
2. Reseat affected DIMM (Note: The event Log might contain a recent FQXSFMA0011I event denoting
detected change in DIMM population that could be related to this problem.)
3. Restore A/C power and power on the system.
4. Check Lenovo support site for an applicable service bulletin or firmware update that applies to this
memory error.
5. If the problem persists, collect Service Data logs and contact Lenovo Support.
• FQXSFPU0001N: An unsupported processor has been detected.
Severity: Error
User Action:
Complete the following steps:
1. Check Lenovo support site for a firmware update required for this processor and install that update, if
applicable.
2. If the problem persists, collect Service Data logs.
3. Contact Lenovo Support.
• FQXSFPU0002N: An invalid processor type has been detected.
Severity: Error
User Action:
Complete the following steps:
1. Verify that the Processor is a valid option that is listed as a Server Proven device for this system. If a
non-supported processor is identified, remove that Processor or replace with a supported Processor.
158
ThinkSystem SD650 V3 / ThinkSystem SD650-I V3 Neptune DWC Trays and DW612S Neptune DWC Enclosure Messages and