Connect Power - Chamberlain 8500W-267 Instruction Manual

Wall mount wi-fi garage door opener
Table of Contents

Advertisement

Installation
8

Connect Power

To avoid installation difficulties, do not
run the garage door opener at this time.
To reduce the risk of electric shock, your
garage door opener has a grounding type
plug with a third grounding pin. This plug
will only fit into a grounding type outlet. If
the plug doesn't fit into the outlet you have,
contact a qualified electrician to install the
proper outlet.
There are two options for connecting
power:
OPTION A: TYPICAL WIRING
1.
Plug in the garage door opener into a
grounded outlet.
2.
DO NOT run garage door opener at
this time.
OPTION B: PERMANENT WIRING
CONNECTION
If permanent wiring is required by
your local code, refer to the following
procedure.
To make a permanent connection through
the 7/8 inch hole in the back of the garage
door opener (according to local code):
1.
Be sure power is NOT connected to
the opener, and disconnect power to
circuit.
2.
Remove the garage door opener from
the torsion bar, remove cover screws
and set the cover aside.
3.
Cut the line cord 6" (15.2 cm) above
the strain relief.
4.
Squeeze the strain relief and push
into motor unit, then remove the
strain relief from the line cord.
5.
Install a 90° conduit (not provided)
or flex cable adapter (not provided)
to the 7/8" hole. Reinstall garage door
opener to torsion bar.
6.
Run wires through conduit, cut to
proper length and strip installation.
7.
Strip 1/2" (1.3 cm) of insulation from
the existing black, white and green
wires.
8.
Connect the line to the black wire and
neutral to the white wire with wire
nuts (not provided). Connect ground
wire to the green ground screw.
9.
Properly secure wires under plastic
ties so that they do not come into
contact with moving parts.
10. Reinstall cover.
RIGHT
WRONG
RIGHT
To prevent possible SERIOUS INJURY or DEATH from electrocution or fire:
• Be sure power is NOT connected to the opener, and disconnect power to circuit
BEFORE removing cover to establish permanent wiring connection.
• Garage door installation and wiring MUST be in compliance with ALL local electrical
and building codes.
• NEVER use an extension cord, 2-wire adapter or change plug in ANY way to make it
fit outlet. Be sure the opener is grounded.
RIGHT
RIGHT
RIGHT
Flexible
Conduit
17
WRONG
WRONG
WRONG
WRONG
Green Wire
90˚
Connector
(Not
Provided)
BACK VIEW
Green
Ground
Screw
Ground Wire
PERMANENT WIRING
PERMANENT WIRING
CONNECTION
CONNECTION
Ground Tab
Ground Tab
Green
Green
Ground Screw
Ground Screw
Ground Wire
Ground Wire
White Wire
White Wire
PERMANENT WIRING
PERMANENT WIRING
CONNECTION
CONNECTION
Ground Tab
Ground Tab
Green
Green
Ground Screw
Ground Screw
Black Wire
Ground Wire
Ground Wire
White Wire
Wire Nuts
(Not Provided
Black Wire
White Wire
Black
Black
Wire
Wire
Black
Bla
Black
Blac
Wire
Wire
White Wire
White Wire

Advertisement

Table of Contents
loading

This manual is also suitable for:

8500w

Table of Contents