Chamberlain 8500C Manual

Chamberlain 8500C Manual

Wall mount garage door opener
Hide thumbs Also See for 8500C:
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

Wall Mount Garage Door Opener
Install on Sectional Doors with Torsion Assemblies Only
This product is intended for installation only by trained garage door technicians. This
product may require adjustments to door springs and or track configurations. This
product is not intended for use on low headroom tracks or garage doors utilizing
extension springs.
• Please read this manual and the enclosed safety materials carefully!
• Fasten the manual near the garage door after installation.
• The door WILL NOT CLOSE unless the Protector System
are connected and properly aligned.
• Periodic checks of the garage door opener are required to ensure safe operation.
• The model number label is located behind the hinged door of your opener.
• DO NOT exceed 10 complete cycles of door operation per hour.
• This garage door opener is ONLY compatible with myQ
accessories.
LiftMaster
300 Windsor Drive
Oak Brook, IL 60523
Model 8500C
For Residential and Light Duty Commercial Use
and cable tension monitor
®
and Security+ 2.0
®
®

Advertisement

Table of Contents
loading

Summary of Contents for Chamberlain 8500C

  • Page 1 Wall Mount Garage Door Opener Model 8500C For Residential and Light Duty Commercial Use Install on Sectional Doors with Torsion Assemblies Only This product is intended for installation only by trained garage door technicians. This product may require adjustments to door springs and or track configurations. This product is not intended for use on low headroom tracks or garage doors utilizing extension springs.
  • Page 2: Table Of Contents

    Table of Contents ADJUSTMENT MAINTENANCE ......29 INTRODUCTION Program the Travel Limits .......19 Care of Your Garage Door Opener ...29 Safety Symbol and Signal Word Review ...2 Set the Force ...........20 Planning ............3 TROUBLESHOOTING Test the Safety Reversal System .....21 Preparing Your Garage Door .....4 Diagnostic Chart ........30 Test the Protector System...
  • Page 3: Planning

    Introduction Planning Survey your garage area to see if any of the conditions below apply to your installation. NOTE: Inspect the torsion bar while the Depending on your requirements, additional materials may be required. door is raised and lowered. It is important that there is no noticeable movement up THIS GARAGE DOOR OPENER IS COMPATIBLE WITH: and down or left and right.
  • Page 4: Preparing Your Garage Door

    Introduction Preparing Your Garage Door BEFORE YOU BEGIN: To prevent possible SERIOUS INJURY or DEATH: • ALWAYS call a trained door systems technician if garage door binds, sticks, or is • Disable locks. out of balance. An unbalanced garage door may NOT reverse when required. •...
  • Page 5: Carton Inventory

    Introduction Carton Inventory Accessories included with the garage door opener will vary depending on the model purchased. If anything is missing, carefully check the packing material. 2 Conductor Bell Wire White & Remote Light White/Red (Garage Door Opener Light) with Hardware Bag Collar with Set Screws The Protector System...
  • Page 6: Assembly

    Assembly Attach the Collar to the Garage Door Opener To avoid installation difficulties, do not run the garage door garage door opener until instructed to do so. To prevent possible SERIOUS INJURY The garage door opener can be installed on either side of the door (see Planning section or DEATH, the collar MUST be properly page 3).
  • Page 7: Attach Mounting Bracket To Garage Door Opener

    Assembly Attach Mounting Bracket to Garage Door Opener HARDWARE Loosely attach slotted side of mounting bracket to the same side of the garage door Screw opener as the collar, using screws provided. #10-32 (2) NOTE: Do not tighten screws until instructed. Socket Wrench Installation IMPORTANT INSTALLATION INSTRUCTIONS...
  • Page 8: Position And Mount The Garage Door Opener

    Installation Position and Mount the Garage Door Opener NOTE: For additional mounting options refer to the accessories page. To prevent possible SERIOUS INJURY Close the garage door completely. or DEATH: Slide the garage door opener onto the end of the torsion bar. If the torsion bar is too •...
  • Page 9: Attach The Emergency Release Rope And Handle

    Installation Attach the Emergency Release Rope and Handle Thread one end of the rope through the hole in the top of the red handle so To prevent possible SERIOUS INJURY “NOTICE” reads right side up. Secure with an overhand knot at least 1 inch (2.5 cm) or DEATH from a falling garage door: from the end of the rope to prevent slipping.
  • Page 10: Attach The Cable Tension Monitor (Required)

    Installation Attach the Cable Tension Monitor (Required) The cable tension monitor MUST be NOTE: The cable tension monitor is shipped for left side installation. It is recommended that the cable tension monitor be installed on the same side of the door as the garage connected and properly installed before door opener.
  • Page 11: Install The Door Control (Myq Control Panel)

    Installation Install the Door Control (myQ Control Panel) Install door control within sight of garage door, out of reach of small children at a minimum height of 5 feet (1.5 m) above floors, landings, steps or any other adjacent To prevent possible SERIOUS INJURY or walking surface, and away from ALL moving parts of door.
  • Page 12: Install Remote Light

    Installation IMPORTANT INSTALLATION INSTRUCTIONS To reduce the risk of SEVERE INJURY or DEATH: 1. This portable luminaire has a polarized plug (one blade 4. If it still does not fit, contact a qualified electrician. is wider than the other) as a feature to reduce the risk of 5.
  • Page 13: Install The Protector System

    Installation Install the Protector System ® The safety reversing sensor must be connected and aligned correctly before the garage door will move in the down direction. This is a required safety device and cannot be disabled. Be sure power is NOT connected to the garage door opener BEFORE installing IMPORTANT INFORMATION ABOUT THE SAFETY REVERSING SENSOR the safety reversing sensor.
  • Page 14 Installation INSTALLING THE BRACKETS Be sure power to the opener is disconnected. Install and align the brackets so the safety reversing sensors will face each other across the garage door, with the beam no higher than 6" (15 cm) above the floor. Choose one of the following installations. OPTION A: Track Installation Slip the curved arms over the Door Track...
  • Page 15 Installation MOUNTING THE SAFETY REVERSING SENSORS HARDWARE 1. Slide a hex screw into the slot on each sensor. Hex Screw 10-24 (2) 2. Use wing nuts to fasten safety reversing sensors to brackets, with lenses pointing toward each other across the door. Be sure the lens is not obstructed by a bracket extension.
  • Page 16: Connect Power

    RIGHT WRONG RIGHT WRONG Installation PERMANENT WIRING PERMANENT WIRING CONNECTION CONNECTION Connect Power Ground Tab Ground Tab To avoid installation difficulties, do not Green Green Ground Screw run the garage door opener at this time. Ground Screw To prevent possible SERIOUS INJURY or DEATH from electrocution or fire: To reduce the risk of electric shock, your Black Black...
  • Page 17 Installation ENSURE THE SAFETY REVERSING SENSORS ARE ALIGNED The door will not close if the sensors have not been installed and aligned correctly. When the light beam is obstructed or misaligned while the door is closing, the door will reverse. If the door is already open, it will not close. The sensors can be aligned by loosening the wing nuts, aligning the sensors, and tightening the wing nuts.
  • Page 18: Install The Battery Backup (Optional)

    Installation Install the Battery Backup (optional) When in Battery Backup mode, wireless myQ devices and Timer-To-Close will be disabled. If the optional Battery Backup is part of this installation, it should be installed at this time. The Battery Backup can be mounted to either the ceiling or a wall within 3 feet (.9 m) of the garage door opener.
  • Page 19: Adjustment

    Adjustment Program the Travel Limits Travel limits regulate the points at which the door will stop when moving up or down. Without a properly installed safety Adjust the position of the door by using the black and yellow buttons. Black moves the reversal system, persons (particularly door UP (open) and yellow moves the door DOWN (close).
  • Page 20: Set The Force

    Adjustment Set the Force The force setting measures the amount of force required to open and close the door. Push the yellow button twice to enter into the Force Adjustment Mode. The LED will Without a properly installed safety flash quickly. reversal system, persons (particularly small children) could be SERIOUSLY Push the door control or programmed remote control.
  • Page 21: Test The Safety Reversal System

    Adjustment Test the Safety Reversal System TEST Without a properly installed safety With the door fully open, place a 1-1/2 inch (3.8 cm) board (or a 2x4 laid flat) on the reversal system, persons (particularly floor, centered under the garage door. small children) could be SERIOUSLY Operate the door in the down direction.
  • Page 22: Test Cable Tension Monitor

    Adjustment Test Cable Tension Monitor With the door fully closed, push on To prevent possible SERIOUS INJURY the front of the cable tension monitor. or DEATH from a falling garage door: A click should be heard. If there is • If possible, use emergency release no click, the roller may be hitting the Roller handle to disengage door ONLY when...
  • Page 23: Operation

    Operation IMPORTANT SAFETY INSTRUCTIONS To reduce the risk of SEVERE INJURY or DEATH: 1. Read and follow ALL warnings and instructions. 9. Safety reversal system MUST be tested every month. Door MUST reverse on contact with 1-1/2" (3.8 cm) high object 2.
  • Page 24: Using The Door Control (Myq Control Panel)

    Operation Using the Door Control (myQ Control Panel) NOTE: Due to power consumption this door control (Model 889LM) cannot be used in conjunction with another wired door control connected to your garage door opener. If an additional door control is needed, the wireless door control model 885LM can be programmed to the door control (Model 889LM).
  • Page 25: Using The Remote Control

    Operation Using the Remote Control Press and hold the button down until the door or gate starts to move. The remote control will operate from up to 3 car lengths away on typical installations. Installations and conditions vary, contact an installing dealer for more information.
  • Page 26: Programming

    Programming Your hand-held remote control (model 893MAX) has already programmed to the door control (myQ Control Panel) at the factory. Below are instructions for programming additional remote controls and keyless entries to the door control. NOTE: Use the learn button on the door control to program all accessories. The yellow learn button on the garage door opener will NOT program accessories.
  • Page 27: Liftmaster ® Internet Gateway (Not Provided)

    Programming LiftMaster Internet Gateway (Not Provided) ® The LiftMaster Internet Gateway gives you control of your garage door from your internet ® Model 828LM connected computer or mobile device. LiftMaster Internet ® Gateway To program your myQ Control Panel to the LiftMaster Internet Gateway: ®...
  • Page 28: Additional Programming For The Keyless Entry (Not Provided)

    Programming Additional Programming for the Keyless Entry (Not Provided) TO CHANGE AN EXISTING, KNOWN PIN If the existing PIN is known, it may be changed by one person without using a ladder. Press the four buttons for the present PIN, then press and hold the # button. Release the # button. Press the new 4-digit PIN you have chosen, then press Enter.
  • Page 29: Maintenance

    Maintenance Care of Your Garage Door Opener MAINTENANCE SCHEDULE Once a Month • Manually operate door. If it is unbalanced or binding, call a trained door systems technician. • Check to be sure door opens and closes fully. Adjust limits and/or force if necessary (see Adjustment Steps 1 and 2).
  • Page 30: Troubleshooting Diagnostic Chart

    Troubleshooting Garage Door Opener Diagnostic Chart Your garage door opener is programmed with self-diagnostic capabilities. The diagnostic LED will flash a number of times, then pause, signifying it has found a potential issue. Consult Diagnostic Chart below. Diagnostic Installed Installed Safety Reversing Safety Reversing Sensor...
  • Page 31: Troubleshooting

    Troubleshooting Troubleshooting The garage door doesn't operate from the myQ Home Control App. • When using Model 580LM Alternate Power Supply or when in Battery Backup mode, the LiftMaster Internet Gateway will not ® activate the garage door through the myQ Home Control App. If you wish to use the LiftMaster Internet Gateway with your garage ®...
  • Page 32: Troubleshooting (Continued)

    Troubleshooting Troubleshooting (Continued) My door will not close: The safety reversing sensor must be connected and aligned correctly before the garage door opener will move in the down direction. • Verify the safety sensors are properly installed, aligned and free of any obstructions. The garage door opener strains to operate door: •...
  • Page 33: Repair Parts Installation Parts

    Repair Parts Installation Parts PART PART DESCRIPTION DESCRIPTION 29B137 Remote control visor clip 41D96-1 Light lens for light 10A20 3V CR2032 Lithium battery 041-0136 Safety sensor kit: receiving and sending sensors with 2-conductor wire 041A4582 Emergency release rope & handle assembly 380LM Remote Light (garage door opener...
  • Page 34: Garage Door Opener Assembly Parts

    Repair Parts Garage Door Opener Assembly Parts PART PART DESCRIPTION DESCRIPTION 041DJ002 Logic board complete with plate 41A6095 Motor with bracket 41A6408 Travel Module 41B122 Power cord 41C168 Transformer 041A6348-1 Cover Contact Information Address repair parts order to: For installation and service LiftMaster information visit us online at: 6050 S.
  • Page 35: Accessories

    Includes visor clip. Mini 3-Button MAX Remote Control 480LM Alternate Mounting Kit: 893LM This kit allows model 8500C MYQ ACCESSORIES to be mounted below the 3-Button Remote Control: torsion bar in the case where 828LM Includes visor clip.
  • Page 36: Warranty

    Warranty LIFTMASTER LIMITED WARRANTY ® LiftMaster (“Seller”) warrants to the first retail purchaser of this product, for the residence in which this product ® is originally installed, that it is free from defects in materials and/or workmanship for a specific period of time as defined below (the “Warranty Period”).
  • Page 37: Automatic Garage Door Opener Safety & Maintenance Guide

    Automatic Garage Door Opener Safety & Maintenance Guide Garage Door Opener Safety – An Automatic Decision A garage door is the largest moving object in the home. An improperly adjusted garage door and opener can exert deadly force when the door closes – which could lead to entrapment of children or adults and subsequent injury or death.
  • Page 38 Routine Maintenance Can Prevent Tragedies Make monthly inspection and testing of your garage door and opener system a part of your regular routine. Review your owner’s manual for both the door and door opener. If you don’t have the owner’s manuals, contact the manufacturer(s) and request a copy for your specific model(s).
  • Page 39 Ouvre-porte de garage à montage mural Modèle 8500C Pour usage résidentiel et commercial léger Installer uniquement sur les portes sectionnelles avec assemblages à torsion Ce produit est destiné à être installé uniquement par des techniciens qualifiés en matière de portes de garage. Ce produit peut nécessiter un ajustement des ressorts de la porte et/ou de la configuration des rails.
  • Page 40: Introduction

    Table des matières RÉGLAGE ENTRETIEN ......67 INTRODUCTION Programmer les limites de déplacement ..57 Utilisation de votre ouvre-porte de garage ..67 Examen des symboles de sécurité et des notes d’avertissement ....40 Régler la force .........58 DÉPANNAGE Planification ..........41 Tester le système d’inversion de sécurité ...59 Tableau de diagnostic ......68 Préparez votre porte de garage ....42 Tester le Protector System...
  • Page 41: Planification

    Introduction Planification Examinez la zone de votre garage pour voir si l’une des conditions ci-dessous s’applique REMARQUE : Inspectez la barre de torsion à votre installation. En fonction de vos besoins, des matériaux supplémentaires peuvent lorsque la porte est levée et abaissée. Il est être nécessaires.
  • Page 42: Préparez Votre Porte De Garage

    Introduction Préparez votre porte de garage Pour éviter d’éventuelles BLESSURES GRAVES voire MORTELLES : AVANT DE COMMENCER : • Appelez TOUJOURS un technicien qualifié en systèmes de porte si la porte de • Désactivez les verrous. garage se coince, colle ou est déséquilibrée. Une porte de garage déséquilibrée •...
  • Page 43: Inventaire Du Carton

    Introduction Inventaire du carton Les accessoires inclus avec l’ouvre-porte de garage varient en fonction du modèle acheté. Si quelque chose manque, vérifiez soigneusement le matériel d’emballage. Fil de sonnette à 2 conducteurs blanc Lampe à distance (lampe et blanc/rouge pour ouvre-porte de garage) avec sac de matériel Collier avec...
  • Page 44: Assemblage

    Assemblage Fixer le collier à l’ouvre-porte de garage Pour éviter les difficultés d’installation, ne faites pas fonctionner l’ouvre-porte de garage avant d’y être invité. Pour éviter d’éventuelles BLESSURES GRAVES ou MORTELLES, le collier L’ouvre-porte de garage peut être installé d’un côté ou l’autre de la porte (voir la section DOIT être serré...
  • Page 45: Fixez Les Supports De Montage Sur L'ouvre-Porte De Garage

    Assemblage Fixez les supports de montage sur l’ouvre-porte de MATÉRIEL garage Fixez sans serrer le côté fendu du support de montage sur le même côté de l’ouvre n° 10-32 (2) porte de garage que le collier à l’aide des vis de montage fournies. REMARQUE : Ne serrez pas les vis du support de montage avant d’y être invité.
  • Page 46: Positionner Et Monter L'ouvre-Porte De Garage

    Installation Positionner et monter l’ouvre-porte de garage. REMARQUE : Pour des options de montage supplémentaires, consultez la page des Pour éviter d’éventuelles BLESSURES accessoires. GRAVES voire MORTELLES : Fermez complètement la porte. • Des ancrages à béton DOIVENT être utilisés si le support est monté dans Faites glisser l’ouvre-porte de garage sur l’extrémité...
  • Page 47: Déverrouillage D'urgence

    Installation Fixez la corde et la poignée de déclenchement d’urgence Pour éviter d’éventuelles BLESSURES Enfilez une extrémité de la corde dans le trou situé en haut de la poignée rouge de GRAVES voire MORTELLES causées façon à ce que « AVIS » se lise à l’endroit. Fixez avec un nœud simple à un minimum par une porte de garage qui tombe : de 1 po (2,5 cm) de l’extrémité...
  • Page 48: Fixer Le Moniteur De Tension Du Câble (Requis)

    Installation Fixer le moniteur de tension du câble (requis) Le moniteur de tension de câble DOIT être REMARQUE : Le moniteur de tension de câble est expédié pour une installation du côté gauche. connecté et aligné correctement avant que Nous recommandons d’installer le contrôleur de tension de câble du même côté que l’ouvre-porte l’ouvre-porte de garage fasse descendre de garage.
  • Page 49: Installer La Commande De Porte (Panneau De Commande Myq)

    Installation Installer la commande de porte (panneau de commande myQ) Pour éviter d’éventuelles BLESSURES GRAVES voire MORTELLES par électrocution : Installez la commande de porte à portée de vue de la porte de garage, hors de portée • Vérifiez que l’alimentation n’est PAS des jeunes enfants, à...
  • Page 50: Installer La Lumière À Distance

    Installation INSTRUCTIONS D’INSTALLATION IMPORTANTES Pour réduire le risque de BLESSURES GRAVES voire MORTELLES : 1. Ce luminaire portable a une fiche polarisée (une broche plus 4. Si elle ne rentre toujours pas, contacter un électricien qualifié. large que l’autre) – c’est une protection qui réduit le risque 5.
  • Page 51: Installer Le Protector System

    Installation Installer le Protector System ® Le capteur d’inversion de sécurité doit être connecté et aligné correctement avant que l’ouvre-porte de garage fasse descendre la porte. Ce dispositif de sécurité est requis et ne peut pas être désactivé. Vérifiez que l’alimentation n’est PAS connectée à...
  • Page 52 Installation INSTALLATION DES SUPPORTS Assurez-vous que l’alimentation de l’ouvre-porte est débranchée. Installez et alignez les supports de sorte que les capteurs d’inversion de sécurité se fassent face de part et d’autre de la porte de garage, la poutre ne dépassant pas 6 po (15 cm) au-dessus du sol. Choisissez l’une des installations suivantes.
  • Page 53 Installation MONTAGE DES CAPTEURS D’INVERSION DE SÉCURITÉ MATÉRIEL 1. Faites glisser une vis hexagonale dans la fente de chaque capteur. Vis à six pans 10-24 (2) Hex Screw 10-24 (2) 2. Utilisez des écrous à oreilles pour fixer les capteurs d’inversion de sécurité aux supports, les lentilles étant orientées l’une vers l’autre à...
  • Page 54: Connecter L'alimentation

    Installation RIGHT WRONG RIGHT WRONG PERMANENT WIRING PERMANENT WIRING CONNECTION CONNECTION Connectez l’alimentation Pour éviter les difficultés d’installation, assurez-vous de ne pas faire fonctionner Ground Tab Ground Tab l’ouvre-porte à ce moment-là. Pour éviter les risques de BLESSURES GRAVES voire MORTELLES par électrocution Green Green ou incendie :...
  • Page 55 Installation ASSUREZ-VOUS QUE LES CAPTEURS D’INVERSION DE SÉCURITÉ SONT ALIGNÉS La porte ne se fermera pas si les capteurs n’ont pas été installés et alignés correctement. Lorsque le faisceau lumineux est obstrué ou mal aligné pendant la fermeture de la porte, celle-ci s’inverse.
  • Page 56: Installer La Batterie De Secours (En Option)

    Installation Installer la batterie de secours (en option) En mode Batterie de secours, les dispositifs myQ sans fil et la TTC sont désactivés. Si la batterie de secours en option fait partie de cette installation, elle doit être installée à ce moment-là.
  • Page 57: Réglage

    Réglage Programmer les limites de déplacement Les limites de déplacement règlent les points auxquels la porte s’arrête lorsqu’elle monte ou descend. Si le capteur d’inversion de sécurité n’est pas installé correctement, Réglez la position de la porte à l’aide des boutons noir et jaune. Le noir déplace la porte les personnes (en particulier les vers le haut (ouverture) et le jaune déplace la porte vers le bas (fermeture).
  • Page 58: Régler La Force

    Réglage Régler la force Le réglage de la force mesure la quantité de force nécessaire pour ouvrir et fermer la porte. Si le capteur d’inversion de sécurité n’est pas installé correctement, Appuyez deux fois sur le bouton jaune pour entrer dans le mode de réglage de la les personnes (en particulier les force.
  • Page 59: Tester Le Système D'inversion De Sécurité

    Réglage Tester le système d’inversion de sécurité Si le capteur d’inversion de sécurité n’est TEST pas installé correctement, les personnes La porte étant complètement ouverte, placez une planche de 1,5 po (3,8 cm) ou un (en particulier les jeunes enfants) 2x4 posé à plat, centré(e) sous la porte du garage. peuvent SUBIR DES BLESSURES GRAVES voire MORTELLES par une Faites fonctionner la porte dans le sens de la descente.
  • Page 60: Tester Le Moniteur De Tension De Câble

    Réglage Tester le moniteur de tension de câble La porte étant complètement fermée, Pour éviter d’éventuelles BLESSURES appuyez sur l’avant du moniteur de GRAVES voire MORTELLES causées tension de câble. Un clic devrait être par une porte de garage qui tombe : entendu.
  • Page 61: Fonctionnement

    Fonctionnement CONSIGNES DE SÉCURITÉ IMPORTANTES Pour réduire le risque de BLESSURES GRAVES voire MORTELLES : 1. Lisez et suivez TOUS les avertissements et les instructions. 9. Le système d’inversion de sécurité DOIT être testé tous les mois. La porte DOIT s’inverser au contact d’un objet de 3,8 cm 2.
  • Page 62: Utilisation De La Commande De Porte (Panneau De Commande Myq)

    Fonctionnement Utilisation de la commande de porte (panneau de commande myQ) REMARQUE : En raison de la consommation d’énergie, cette commande de porte (modèle 889LM) ne peut pas être utilisée conjointement avec une autre commande de porte câblée connectée à votre ouvre-porte de garage. Si une commande de porte supplémentaire est nécessaire, la commande de porte sans fil modèle 885LM peut être programmée sur la commande de porte (modèle 889LM).
  • Page 63: Utilisation De La Télécommande

    Fonctionnement Utilisation de la télécommande Appuyez sur le bouton et maintenez-le enfoncé jusqu’à ce que la porte ou le portail commence à bouger. La télécommande fonctionnera jusqu’à une distance de 3 longueurs de voiture sur des installations typiques. Les installations et les conditions varient, contactez un revendeur installateur pour plus d’informations.
  • Page 64: Programmation

    Programmation Votre télécommande manuelle (modèle 893MAX) a déjà été programmée en usine sur la commande de la porte (panneau de commande myQ). Vous trouverez ci-dessous les instructions pour programmer des télécommandes et des entrées sans clé supplémentaires sur la commande de la porte.
  • Page 65: Passerelle Internet Liftmaster ® (Non Fournie)

    Programmation Passerelle Internet LiftMaster (non fournie) ® La passerelle Internet LiftMaster vous donne le contrôle de votre porte de garage à partir ® Passerelle Internet de votre ordinateur ou appareil mobile connecté à Internet. LiftMaster modèle ® 828LM Pour programmer votre panneau de contrôle myQ à la passerelle Internet LiftMaster  : ®...
  • Page 66: Programmation Supplémentaire Pour L'entrée Sans Clé (Non Fournie)

    Programmation Programmation supplémentaire pour l’entrée sans clé (non fournie) POUR MODIFIER UN CODE NIP EXISTANT ET CONNU Si le code NIP existant est connu, il peut être modifié par une seule personne sans utiliser d’échelle. Appuyez sur les quatre boutons correspondant au code NIP actuel, puis appuyez sur le bouton # et maintenez-le enfoncé. Relâchez le bouton CLOSE (fermeture).
  • Page 67: Entretien

    Entretien Utilisation de votre ouvre-porte de garage PLANIFICATION DE L’ENTRETIEN Une fois par mois • Activez manuellement la porte. Si elle est déséquilibrée ou pliée, appelez un technicien qualifié en systèmes de porte. • Vérifiez que la porte s’ouvre et se ferme complètement. Ajustez les limites et/ou la force si nécessaire (voir les étapes de réglage 1 et 2).
  • Page 68: Dépannage Tableau De Diagnostic

    Dépannage Ouvre-porte de garage Tableau des diagnostics Votre ouvre-porte de garage est programmé pour s’autodiagnostiquer. Le voyant de diagnostic clignote un certain nombre de fois, puis s’arrête, ce qui signifie qu’il a trouvé un problème potentiel. Consultez le tableau de diagnostic ci-dessous. DEL de diagnostic Installed...
  • Page 69: Dépannage

    Dépannage Dépannage La porte de garage ne fonctionne pas à partir de l’application myQ Home Control App. • Lorsque vous utilisez l’alimentation de rechange du modèle 580LM ou lorsque vous êtes en mode de batterie de secours, la passerelle Internet LiftMaster n’activera pas la porte de garage par le biais de cette application.
  • Page 70: Dépannage (Suite)

    Dépannage Dépannage (suite) Ma porte ne se ferme pas : Le capteur d’inversion de sécurité doit être connecté et aligné correctement avant que l’ouvre-porte de garage fasse descendre la porte. • Vérifiez que les capteurs de sécurité sont installés et alignés correctement et qu’ils ne sont pas obstrués. L’ouvre-porte de garage semble forcer pour ouvrir la porte : •...
  • Page 71: Pièces Détachées

    Pièces de rechange Pièces d’installation RÉF. DESCRIPTION RÉF. DESCRIPTION 29B137 Clip de pare-soleil pour la télécommande 41D96-1 Lentille pour lampe 10A20 Batterie au lithium 3 V CR2032 041-0136 Kit de capteurs de sécurité : capteurs de réception et d’envoi avec deux fils 041A4582 Ensemble corde et poignée de conducteurs...
  • Page 72: Pièces D'assemblage De L'ouvre-Porte De Garage

    Pièces de rechange Pièces d’assemblage de l’ouvre-porte de garage RÉF. DESCRIPTION RÉF. DESCRIPTION 041DJ002 Carte mère complète avec plaque 41A6095 Moteur avec support 41A6408 Module de déplacement 41B122 Cordon d’alimentation 41C168 Transformateur 041A6348-1 Couvercle Coordonnées de contact Adressez votre commande de pièces de rechange à : Pour l’information relative à...
  • Page 73: Accessoires

    480LM Kit de montage alternatif : 893LM Ce kit permet de monter le ACCESSOIRES MYQ modèle 8500C sous la barre Télécommande à 3 de torsion dans le cas où boutons : 828LM la barre de torsion n’est Comprend une pince pour Passerelle Internet LiftMaster  :...
  • Page 74: Garantie

    Garantie GARANTIE LIMITÉE LIFTMASTER ® LiftMaster (le « Vendeur ») garantit au premier acheteur au détail de ce produit, pour la résidence dans laquelle ® ce produit est installé à l’origine, qu’il est exempt de défauts de matériaux et/ou de fabrication pendant une période spécifique définie ci-dessous (la « Période de garantie »).
  • Page 75: Guide De Sécurité Et D'entretien De L'ouvre-Porte De Garage Automatique

    Guide de sécurité et d’entretien de l’ouvre-porte de garage automatique Sécurité de l’ouvre-porte de garage – Une décision automatique La porte de garage est le plus grand objet mobile d’une maison. Le réglage inapproprié de la porte de garage et de l’ouvre- porte peut entraîner une force mortelle lorsque la porte ferme, ce qui pourrait faire en sorte qu’un enfant ou un adulte soit coincé...
  • Page 76 L’entretien de routine peut éviter des tragédies Faites des inspections et des tests de votre porte de garage et votre système d’ouvre-porte tous les mois en tant que partie de votre routine. Relisez le guide de l’utilisateur de la porte ainsi que de l’ouvre-porte. Si vous n’avez pas de guide de l’utilisateur, communiquez avec le fabriquant et demandez l’exemplaire pour votre modèle précis.

Table of Contents