Weight
Gross (Bare Bone): 34 lbs. (15.5 kg.)
System Cooling
Two (2) 10-cm blower fans
System Input Requirements
AC Input Voltage: 100-240 VAC
Rated Input Current: 8A (115V) to 4A (230V)
Rated Input Frequency: 50-60 Hz
Power Supply
Rated Output Power: 280W (Model# PWS-281-1H)
Rated Output Voltages: +3.3V (15A), +5V (18A), +12V (23A), -12V (1A), +5Vsb
(2A)
BTU Rating
1478 BTUs/hr (for rated output power of 280W)
Operating Environment
Operating Temperature: 10º to 35º C (50º to 95º F)
Non-operating Temperature: -40º to 70º C (-40º to 158º F)
Operating Relative Humidity: 8% to 90% (non-condensing)
Non-operating Relative Humidity: 5 to 95% (non-condensing)
Regulatory Compliance
Electromagnetic Emissions:
FCC Class B, EN 55022 Class B, EN 61000-3-2/-3-3, CISPR 22 Class B
Electromagnetic Immunity:
EN 55024/CISPR 24, (EN 61000-4-2, EN 61000-4-3, EN 61000-4-4,
EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-4-11)
Safety:
EN 60950/IEC 60950-Compliant, UL Listed (USA), CUL Listed (Canada), TUV
Certifi ed (Germany), CE Marking (Europe)