3. F-1002M_J(Z)(-C)(-SC)

Model Number
AC Supply Voltage
Compressor
Gear Motor
Fan Motor
Other
Maximum Fuse Size
Max. HACR Breaker
(USA Only)
Max. Circuit Breaker
(Canada Only)
Minimum Circuit
Ampacity
Design Pressure
Refrigerant
Single Phase
F-1002MAJ(-C) (-SC) F-1002MWJ(-C)
115/60/1
115V 11.2RLA
93LRA
115V 3.0FLA 200W
115V 1.0FLA 1/15HP
115V 0.03A
20 AMPS
20 AMPS
20 AMPS
20 AMPS
HI-467PSI
LO-250PSI
404A 2 LB. 4 OZ.
F-1002MRJZ(-C)(-SC)
115/60/1
115/60/1
115V 10.7RLA
115V 11.2RLA
93LRA
93LRA
115V 3.0FLA
115V 3.0FLA 200W
200W
– – –
115V 3A MAX
(Fan in URC)
115V 0.03A
115V 0.53A
20 AMPS
20 AMPS
20 AMPS
20 AMPS
20 AMPS
20 AMPS
20 AMPS
20 AMPS
HI-427PSI
HI-467PSI
LO-250PSI
LO-250PSI
404A 12.3 OZ.
404A
Total Refrigerant
Charge with Hoshizaki
Remote Condenser
Unit URC-5FZ: 4 LB.
1.2 OZ.
8
F-1002MLJ(-C)
115/60/1
– – –
115V 3.0FLA
200W
– – –
115V 0.53A
15 AMPS
15 AMPS
15 AMPS
15 AMPS
HI-467PSI
LO-250PSI
Use only with
404A, 407A, or
407F

Advertisement

Table of Contents
loading