Maintenance Schedule - Hoshizaki F-1002MAJ-SC Instruction Manual

Modular flaker
Table of Contents

Advertisement

A. Maintenance Schedule
The maintenance schedule below is a guideline. More frequent maintenance may be
required depending on water quality, the appliance's environment, and local sanitation
regulations.
Frequency
Area
Daily
Scoop
Bi-Weekly
Air Filters
Monthly
External Water Filters
Icemaker Exterior
Infrared Sensor Lens;
Underside of Icemaker
and Top Kits; Bin Door
and Snout
Every 6
Icemaker and
Months
Dispenser Unit/Ice
Storage Bin
Evaporator
Condensate Drain
Pan and Gear
Motor Drain Pan
Icemaker and
Dispenser Unit/Ice
Storage Bin Drains
Extruding Head
Seal Bolts
Yearly
Inlet Water Valve
and Drain Valve
Water Hoses
Condenser
Icemaker
Upper Bearing
(extruding head)
After
Upper Bearing
3 Years,
(extruding head);
then Yearly
Lower Bearing
and O-Ring
(lower housing);
Mechanical
Seal; Evaporator
Cylinder; Auger

Maintenance Schedule

Task
Clean the ice scoop using a neutral cleaner. Rinse thoroughly after
cleaning.
Inspect. Wash with warm water and neutral cleaner if dirty.
Check for proper pressure and change if necessary.
Wipe down with a clean, soft cloth. Use a damp cloth containing a
neutral cleaner to wipe off oil or dirt build up. Clean any chlorine
staining (rust colored spots) using a non-abrasive cleanser.
Wipe down with a clean cloth and warm water.
Clean and sanitize per the cleaning and sanitizing instructions
provided in this manual.
Wipe down with a clean cloth and warm water. Slowly pour one cup of
sanitizing solution (prepare as outlined in the sanitizing instructions
in this manual) into the evaporator condensate drain pan and then
slowly pour one cup into the gear motor drain pan. Be careful not to
overflow the pans. Repeat with a cup of clean water to rinse.
Check to make sure they are clear.
Inspect for leakage around seal bolts. Tighten (see torque values
below) or replace as necessary. Seal bolts must be replaced once
removed because seal material is one-time use only. If new seal bolts
do not have preapplied threadlocker, apply Loctite 243 or equivalent
threadlocker to seal bolt threads.
• Torque: 11.1 ft-lb/15 N·m
Tighten 2 times. Allow at least 5 sec. in between each tightening.
Close the water supply line shut-off valve and drain the water system.
Clean the inlet water valve screen and clean and inspect the drain
valve.
Inspect the water hoses and clean/replace if necessary.
Inspect. Clean if necessary by using a brush or vacuum cleaner.
Inspect for oil spots, loose components, fasteners, and wires.
Check for wear using .02" round stock or pin gauge. Replace both
upper bearing and lower bearing if wear exceeds factory
recommendations. See the Service Manual for details.
Inspect. Replace both upper bearing and lower bearing if wear
exceeds factory recommendations. Replace the mechanical seal if
the seal's contact surfaces are worn, cracked, or scratched. See the
Service Manual for details.