AudioCodes Mediant 500Li Metal MSBR Hardware Installation Manual

AudioCodes Mediant 500Li Metal MSBR Hardware Installation Manual

Multi-service business router
Hide thumbs Also See for Mediant 500Li Metal MSBR:

Advertisement

Quick Links

Mediant 500 Li MSBR Hardware Installation Manual
Hardware Installation Manual
AudioCodes Mediant™ Multi-Service Business Router Series
Mediant 500Li Metal MSBR

Advertisement

Table of Contents
loading

Summary of Contents for AudioCodes Mediant 500Li Metal MSBR

  • Page 1 Mediant 500 Li MSBR Hardware Installation Manual Hardware Installation Manual AudioCodes Mediant™ Multi-Service Business Router Series Mediant 500Li Metal MSBR...
  • Page 2: Table Of Contents

    Table of Contents Notice ..........................v WEEE EU Directive ..........................v Customer Support ..........................v Stay in the Loop with AudioCodes ....................v Abbreviations and Terminology ......................v Related Documentation ........................v General Notes and Warnings, and Safety Information ..............v Document Revision Record ......................
  • Page 3 Contents Mediant 500Li Connecting Serial Interface to PC ..................34 Connecting a USB Storage Device ..................35 Connecting Power ......................... 35 6.6.1 3-Amp Power Supply Cabling ....................36 6.6.2 5-Amp Power Supply Cabling ....................38 6.6.3 Switching Device On and Off ....................38 Approved Laser SFPs ....................
  • Page 4 Contents Mediant 500Li - iii -...
  • Page 5: Notice

    Please contact your local recycling authority for disposal of this product. Customer Support Customer technical support and services are provided by AudioCodes or by an authorized AudioCodes Service Partner. For more information on how to buy technical support for AudioCodes products contact...
  • Page 6: General Notes And Warnings, And Safety Information

    Prior to installing and operating the device, please read the device's Regulatory Information. Open-source software may have been added and/or amended. For further information, visit AudioCodes website at https://www.audiocodes.com/services- support/open-source or contact your AudioCodes sales representative. - vi...
  • Page 7: Document Revision Record

    LTRT Descrip tion 10612-Reg Compliance Documentation Feedback AudioCodes continually strives to produce high quality documentation. If you have any comments (suggestions or errors) regarding this document, please fill out the Documentation Feedback form on our website at https://online.audiocodes.com/documentation-feedback. - vii...
  • Page 8: Introduction

    Serial console port (RJ-45) for device management ◼ Hardware configurations may change without notice. Currently available hardware configurations are listed in AudioCodes Price Book. For further enquiries, please contact your AudioCodes sales representative. ◼ The SFP module can be used for WAN fiber-optic interface or WAN copper interface.
  • Page 9: Unpacking The Device

    3 x Wi-Fi antennas (depending on ordered model) • 2 x cellular antennas (depending on ordered model) • 1 x AC/DC power adapter Check, retain and process any documents. If there are any damaged or missing items, notify your AudioCodes sales representative. - 2 -...
  • Page 10: Physical Description

    Physical Description Mediant 500Li Physical Description This section provides a physical description of the device. Physical Dimensions and Operating Environment The device's physical dimensions and operating environment are listed in the table below: Table 1: Physical Dimensions and Operating Environment Specification Value Dimensions (H x W x D)
  • Page 11: Led Descriptions

    Physical Description Mediant 500Li The figure above is used only as an example. Available LEDs depend on the ordered hardware configuration. Table 2: Front Panel Description Item # LED Label Description Power Indicates the status of the power supply to the device. For more information, see Section 3.2.1.1 on page 10.
  • Page 12: Status Led

    Physical Description Mediant 500Li 3.2.1.2 Status LED The Status LED indicates the operating status, as described in the table below. Table 4: Status LED Description LED Color LED State Description Green Device is operational. ◼ Initial rebooting stage. Flashing ◼ Software upgrade (.cmp file) in process.
  • Page 13 Physical Description Mediant 500Li 3.2.1.4.2 WAN GE LED The WAN GE LED indicates the status of the Gigabit Ethernet over Copper WAN link, as described in the table below. Table 7: WAN GE LED Description LED Color LED State Description Green WAN GE link established.
  • Page 14: Rear Panel Description

    Physical Description Mediant 500Li Rear Panel Description The device's rear panel is shown in the figure below and described in the subsequent table. Figure 2: Rear Panel The figure above is used only as an example. The hardware configuration depends on the ordered model.
  • Page 15: Lan Interface Leds

    ◼ ◼ GE SFP: SFP module ◼ DSL: DSL interface Note: For available WAN configurations, contact your AudioCodes sales representative. S1 (Slot 1) Up to four Gigabit Ethernet (1000Base-T) ports (RJ-45) for connecting to LAN GE LAN network such as IP phones, computers, and switches. These ports support half- and full-duplex modes, auto-negotiation, and straight or crossover cable detection.
  • Page 16: Mounting The Device

    Wall mounting 19-Inch Rack Mounting You can mount the device in a standard 19-inch rack, using AudioCodes 1U 19-inch rack mount shelf (not supplied). The AudioCodes 1U 19-inch rack mount shelf is not supplied with your product and can be ordered separately from an AudioCodes sales distributor.
  • Page 17 Mediant 500Li To mount the device in a 19-inch rack: Position the rack mount shelf (ordered separately from AudioCodes) in the 19-inch rack, aligning the holes of the shelf's side brackets with the holes of the rack's front posts, as shown in the figure below.
  • Page 18 Mounting the Device Mediant 500Li Figure 5: Positioning Device's Anti-Slide Rubber Legs into Shelf's Openings Make sure the device is firmly mounted on the shelf so it does not horizontally slide in any direction: Figure 6: Device Mounted on Shelf in 19-inch Rack - 11 -...
  • Page 19: Wall Mounting

    Mounting the Device Mediant 500Li Wall Mounting You can mount the device on a wall using the keyholes on the bottom of the device. To mount the device on a wall: Drill three holes in the wall where you want to mount the device, using the distances between the holes as shown in the figure below: •...
  • Page 20 Mounting the Device Mediant 500Li Insert wall anchors of the appropriate size into each hole. - 13 -...
  • Page 21 Mounting the Device Mediant 500Li Thread screws (not supplied) into each of the wall anchors. The recommended screw type is DIN 7982 3.5x25 Phillips flat head. Make sure that the heads extend sufficiently (about 4 mm or 0.157 in.) from the wall for the device's keyholes to hang on: Figure 8: Protruded Screw Distance from Wall Surface Hold the device so that it is orientated with the bottom panel with the keyholes facing the wall and the rear panel with the ports facing your right.
  • Page 22: Wi-Fi Connection

    Wi-Fi Connection Mediant 500Li Wi-Fi Connection Wi-Fi functionality is a customer a separate orderable item. Orienting the Wi-Fi Antennas If you have ordered LAN wireless (Wi-Fi) functionality, the device is shipped with two pre-attached, external Wi-Fi antennas. You can orient the antennas in the vertical plane, from 0 to 180 degrees for optimal wireless transmission and reception.
  • Page 23: Cabling The Device

    Failing to install primary surge protectors and failing to comply with the grounding instructions or any other installation instructions, may cause permanent damage to the device! As most of the installation is the responsibility of the customer, AudioCodes can assume responsibility for damage ◼...
  • Page 24: Connecting To Wan

    Cabling the Device Mediant 500Li Figure 1: Earthing the Device Connecting to WAN This section describes how to cable the WAN port interfaces. The device supports WAN redundancy, whereby multiple WAN interfaces can serve as backups for the primary or a backup WAN interface. For example, if the main WAN interface is Copper GbE and it fails, the device switches over to the fiber-optic WAN interface.
  • Page 25: Connecting Gigabit Ethernet Wan Over Fiber-Optic

    The SFP module and fiber-optic cable are not supplied. It is recommended that you indicated by the cable manufacturer. purchase the SFP modules from AudioCodes. For a list of orderable SFP modules, see To ensure full high-availability capabilities, the configuration of the interface to the IP Appendix on page 39, or contact your AudioCodes sales representative.
  • Page 26 Cabling the Device Mediant 500Li Cable specifications: ◼ WAN fiber-optic interface: LC-type plug ◼ WAN copper interface: see Section 6.1.1 on page 23 To connect the fiber-optic WAN GbE port: Remove the protective dust plug from the SFP transceiver module. Save the dust plugs for future use.
  • Page 27: Connecting Vdsl2 And Adsl2(2+) Wan

    ITU G.991.2 Annex E for Ethernet, also known as EFM or 2Base-TL, as defined in IEEE 802.3ah • 802.1q VLANs over EFM • PPPoE The xDSL interface is a customer-ordered item. For more information, contact your AudioCodes sales representative. Cable specification: Connector: RJ-11 ◼ Connector Pinouts: ◼ Table 13: RJ-11 Connector Pinouts for WAN DSL Function CH0 –...
  • Page 28: Integrated 4G Lte Cellular Modem

    Cabling the Device Mediant 500Li To connect the WAN DSL port: Connect an RJ-11 cable connector to the device’s DSL WAN port (labeled DSL). Connect the other end of the cable to the access point. Figure 14: Cabling DSL WAN Port The DSL filter/splitter is not supplied and should be provided by your service provider.
  • Page 29 Cabling the Device Mediant 500Li The LTE modem contains three variants for worldwide coverage, as listed in the following table: Table 14: LTE Variant Types Type Region Bands ◼ LTE FDD: B1/B3/B5/B7/B8/B20 EMEA and Asia ◼ LTE TDD: B38/B40/B41 WCDMA: B1/B5/B8 ◼...
  • Page 30: Connecting To Lan

    Cabling the Device Mediant 500Li Attach the two cellular antennas (supplied) to the antenna connectors, located on the rear panel, by hand screwing the antennas onto the connectors. Make sure that the antennas are securely fastened to the connectors. Figure 16: Connecting Cellular Antennas ◼...
  • Page 31: Cabling Fxs Interfaces

    Cabling the Device Mediant 500Li Signal Name Ethernet signal pair (1000Base-T) Ethernet signal pair (1000Base-T) Ethernet signal pair (1000Base-T) Ethernet signal pair (1000Base-T) To connect the device to the LAN: Connect one end of a straight-through RJ-45 Cat 5e or Cat 6 cable to the LAN port, located on the rear panel and labeled GE LAN.
  • Page 32: Connecting Serial Interface To Pc

    Cabling the Device Mediant 500Li FXS interface is a customer-ordered item which is supported only on specific ◼ hardware configurations. For more information, contact your AudioCodes sales representative. ◼ The FXS interfaces support loop-start signaling (indoor only). Cable specification: Cable: Standard straight-through RJ-11 telephony cable ◼...
  • Page 33: Connecting A Usb Storage Device

    Cabling the Device Mediant 500Li Figure 21: RS-232 Cable Adapter Table 17: RJ-45 to DB-9 Serial Cable Connector Pinouts RJ-45 DB-9 Female To connect the device's serial interface port to a PC: Connect the RJ-45 connector at the end of the cable to the device's serial port, located on the rear panel and labeled CONSOLE.
  • Page 34: Connecting Power

    Cabling the Device Mediant 500Li Updating the device's configuration from USB ◼ ◼ Saving the current configuration to USB To connect the USB storage device: ◼ Connect the USB storage device to the USB port, located on the rear panel. Figure 23: Connecting USB Storage Device Only a single USB storage (formatted to FAT/FAT32) operation is supported at any given time.
  • Page 35: 3-Amp Power Supply Cabling

    Cabling the Device Mediant 500Li 6.7.1 3-Amp Power Supply Cabling For 3-Amp power supply, the device is shipped with the AC/DC power adapter shown in the figure below. The power adapter also supports interchangeable plugs to suite the electrical wall outlet type requirement of the country in which the device is being installed.
  • Page 36 Cabling the Device Mediant 500Li To connect the device to the power supply using the 3-Amp power adapter: Insert the relevant AC plug into the housing power adapter: Insert the top part of the plug into the upper part of the housing slot (1). Press down on the bottom part of the plug until a "click"...
  • Page 37: 5-Amp Power Supply Cabling

    Cabling the Device Mediant 500Li Plug the power adapter directly into a standard electrical wall outlet. 6.7.2 5-Amp Power Supply Cabling For 5-Amp power supply, the device is shipped with an AC/DC power adapter that supplies 5 amps. The adapter provides an integrated DC power cord with a DC plug for attaching to the device. For the connection to the standard AC electrical wall outlet, an AC power cord with a female, 2-prong plug (C2) on one side for connecting to the AC/DC adapter and a plug on the other end for connecting to electrical wall outlet...
  • Page 38: A Approved Laser Sfps

    Approved Laser SFPs Mediant 500Li Approved Laser SFPs The table below lists the recommended SFPs, which can be ordered from AudioCodes. For installing the SFPs and for fiber-optic WAN cabling, see Section 6.1.2 on page 24. Table 20: Approved SFP Modules...
  • Page 39 Website: https://www.audiocodes.com ©2023 AudioCodes Ltd. All rights reserved. AudioCodes, AC, HD VoIP, HD VoIP Sounds Better, IPmedia, Mediant, MediaPack, What’s Inside Matters, OSN, SmartTAP, User Management Pack, VMAS, VoIPerfect, VoIPerfectHD, Your Gateway To VoIP, 3GX, VocaNom, AudioCodes One Voice, AudioCodes Meeting Insights, and AudioCodes Room Experience are trademarks or registered trademarks of AudioCodes Limited.

Table of Contents